17
GYSFLASH 30-24 HF
EN
BATTERY CHANGE MODE CONFIGURATION
CHANGE BATTERY
12V
CHANGE BATTERY
12V
6V
12V
24V
Start up :
• Connect
1 : Red clamp to the (+) of the battery / battery terminal,
in such a way that the battery can be changed without
disconnecting the clamp.
2 : Black clamp to the vehicle chassis or earth.
• Push the START/STOP key to start the mode.
• During use the current consumed and the instanta-
neous voltage are displayed.
• When changing the battery ensure the polarity is
correct. While exchanging the batteries, be careful
not to disconnect the charger clamps to avoid loss of
electronic data.
STARTING BATTERY CHANGE
CHANGE BATTERY
CHANGE BATTERY
U=12.9V
I=26A
U=12V
Warning:
polarity reversal can damage the vehicle electronics.
POWER SUPPLY MODE (OPTIONAL)
This mode is intended for expert users only. This mode enables the charger to be used as a stabilised power supply, with regulated
voltage and adjustable maximum current. By default this mode is inactive and doesn’t appear in the mode list. It can be activated
via the Advanced menu (see page 19).
Adjustment of the voltage regulation and current limitation :
The voltage regulation can be adjusted from 2V to 30V and the maximum current from 2A to 30A (or from 2A to 15A above 16V):
POWER SUPPLY MODE CONFIGURATION
POWER SUPPLY
U=19.6V
I<15A
POWER SUPPLY
U=19.6V
I<10A
2.0V
2.1V
...
30.0V
2A
3A
...
30A
POWER SUPPLY
U=13.5V
I<30A
2A
3A
...
15A
Start up:
• Push the START/STOP key to start the mode.
• During use the current consumed and the instanta-
neous voltage are displayed.
STARTING POWER SUPPLY
POWER SUPPLY
U=19.6V
I<15A
POWER SUPPLY
U=19.6V
I=10A
NOTE:
Unlike the other modes, when in Power Supply mode, the charger does not compensate cables voltage drop.
In this mode, the voltage displayed is the charger output voltage (and not the voltage on the clamps).
CONFIGURATION MENU
Access to configuration menu :
MODE
3 sec - Mode
To browse in the sub menu press the
«Select» key :
SELECT
languages > restart > lock showroom > charge type > cable check >
ADVANCED MENU > Reset Memory