PPX Series User Manual
168
Connection
PPX
EXT-R
Analog
connector
6
5
Output
Terminal
2 core shielded
wire or twisted
pair
Pin5 → EXT-R
Pin6 → EXT-R
Wire shield → negative (-) output terminal
Steps
1.
Connect the external resistance according to the
connection diagrams above.
2.
Set the CC Control as External R.
Also, set Output Type per application
and turn On Output Enable.
Page 108
3.
Press the Output key. The current
can now be controlled with the
External resistance.
Note
Ensure the resistor(s) and cables used exceed the
isolation voltage of the power supply. For example:
insulation tubes with a withstand voltage higher
than the power supply can be used.
When choosing an external resistor ensure the
resistor can withstand a high degree of heat.
Note
CV and CC Slew Rate Priority (CVLS, CCLS) are
disabled when using external resistance control.
See the CVLS and CCLS Settings on page 51 & 55.