PPX Series User Manual
122
V/I Set
PPX will change to the predefined
V/I settings when trigger-in signal is
received. It is required to set Trigin
Voltage and Trigin Current,
individually before enabling V/I Set.
Memory
PPX will change to the predefined
Trigin Memory when trigger-in signal
is received. It is required to set Trigin
Memory before enabling Memory.
Trigin Voltage &
Trigin Current
6.
Scroll knob key to move between
Trigin Voltage and Trigin Current
fields. Click the knob key to enter
each field, respectively. Scroll the
knob key to adjust value, along
with the arrow keys to change
among digits followed by clicking
the knob key to confirm set value.
Setting Range
Model
Trigin Voltage
Trigin Current
PPX-1005
0.000 ~ 10.500V 0.0000 ~ 5.2500A
PPX-2002
0.000 ~ 21.000V 0.0000 ~ 2.1000A
PPX-2005
0.000 ~ 21.000V 0.0000 ~ 5.2500A
PPX-3601
0.000 ~ 37.800V 0.0000 ~ 1.0500A
PPX-3603
0.000 ~ 37.800V 0.0000 ~ 3.1500A
PPX-10H01
0.000 ~ 105.000V 0.0000 ~ 1.0500A