ANALOG CONTROL
159
A COM
6
This is the common line for external signal pins
1, 2, 3, and 5.
N.C.
7
Not connected.
N.C.
8
Not connected.
OUT ON/OFF
CONT
9
Output on/off line.
On when set to a low TTL signal, Off when set
to a high TTL signal.
On when set to a high TTL signal, Off when set
to a low TTL level signal.
TRIG IN
10
Trigger signal input line.
Pulled down the internal circuit to B COM
using 100kΩ.
The minimum pulse is width is 100us.
TRIG OUT
11
Trigger signal output line.
Outputs a TTL signal when a trigger out
function is activated.
The minimum pulse is width is 1ms.
B COM
12
This is the common line for external signal pins
9, 10, and 11.
N.C.
13
Not connected.
N.C.
14
Not connected.
OUT ON Status 15
On when the output is on (open-collector
photocoupler output).1
CV Status
16
This line is On when the PPX is in CV mode
(open-collector photocoupler output).1
PWR OFF Status 17
Outputs a low level signal when power is
turned off. (open-collector photocoupler
output).1
CC Status
18
This line is On when the PPX is in CC mode
(open-collector photocoupler output).1