33
.............................
CCEC/ OM Manual GlasStile GSR 1.6 EN
07
.2009
Program Options
MODE
- OPERATIONAL MODE
N
Not used on the GlasStile GSR.
PG
Push to Go, if stacking of card signals is required select D from acknowledgement. (Default)
T
Not used on the GlasStile GSR.
DF
Reset all settings to those set during factory testing.
SPEED
- SPEED
Nominal rpm
1
8
2
10 (Default)
3
13
4
16
TIME
– TIME-OUT OF CARD READER SIGNAL
1
15 seconds
2
30 seconds (Default)
3
45 seconds
4
60 seconds
ACK
- ACKNOWLEDGEMENT SIGNAL AND COUNTER IMPULSE
D
During rotation
– If this is selected then stacking of up to five signals is allowed
A
After rotation (Default)
G-POS
- SELECTION OF PANEL AT PROGRAMMING
0
No panel selection, this is the normal position when no panel is to be programmed.
1
Panel 1 (Default)
2
Panel 2 (Default)
3
Panel 3 (Default)
Programming the GlasStile GSR
To enter programming mode the GlasStile GSR must be switched on and in a locked position.
The Hand Held Programmer must be connected to P9 on the PCB.
Before any new settings are made it is important that the present settings are defaulted.
Press
PRG.
The red programme diode lamp will come on.
When the brake has been released, the yellow lamp (GATE CLOSED) extinguishes. The gate
now transmits its set parameters to the programming unit.
Press the MODE push button until DF LED is illuminated, then press send.
You can now adjust speed, time, and acknowledgement settings.
Programming the Wing Positions
If the column has been installed correctly, there is normally no need to adjust the stopping
positions; however, should you need to, please follow the steps below
Select a position using the
G-POS
push button on the programming unit.
Place the panel in the desired position, manually.
Press the
SET G-POS
button. The green lamp will flash in acknowledgement.
Select the new position on the Hand Held Programmer by pressing
G-POS
.
Rotate the column so that the second panel is the same position as the first
SET G-POS
.