22
.............................
CCEC/ OM Manual GlasStile GSR 1.6 EN
07
.2009
Installation Routines
When planning the installation, it is important that everything is measured accurately and that
the cableways are marked out. All cables must be laid according to the specification before
installation begins.
All Electrical work MUST be carried out by a qualified engineer
Marking out
1
Determine the rotor centre location on the floor. Lightly mark out the fixing positions
appropriate to the rotor and casework.
Do not drill fixing holes at this point
.
2
Ensure the floor area conforms to the Site Preparation requirements, especially for
levelness and under floor conduit positions , see Fig 5.1 below.
Centre Column
3
Place the foundation plate and the centre column in the intended position. Turn the centre
column so that the marking „Default home position‟ on the centre column's non-rotating part
ends up in the middle of the passage way to ensure the correct home positions as set in the
factory are achieved.
4 Mark out and drill the M12 holes, using the appropriate "M10" fixing items.
Fig 5.1 - Column Mounting Plate
5. Place the centre column on the foundation plate and adjust vertically, using the adjusting
screws on the centre column‟s base plate. Lock in position using the fixing screws.
6. Fit the M4 x 8 Top Cladding Retaining screw into the chassis leaving approximately 2mm
clearance between the head and surface, see Fig. 5.3, repeating for each wing.
7. Insert the glazed panel making sure that the plastic insulator, packing strip and the plastic
spacer sit between the glass and the metal surrounds to avoid the risk of the glass
cracking, see Fig.5.2, repeating for each wing.
GLSR to stop inline with dimple
mark on Mounting Plate
Conduits to rise in shaded area
Floor anchors positions, to be drilled
during installation, drill 12 dia x 100
deep min. Position tol/- 0.2mm
IMPORTANT
- Any horizontal pipe or conduit
runs below the surface must avoid GLSR fixing
positions
Concrete base