12
.............................
CCEC/ OM Manual GlasStile GSR 1.6 EN
07
.2009
Operating Modes
Card Reader Control - Push to Go
When a signal is applied to one of the two card reader inputs the unit releases the brake and
switches the gate closed output. Passage can now occur within the selected time, if no passage
is started within this time the GlasStile GSR will lock and a new impulse must be given.
The GlasStile GSR starts to rotate in the selected direction once the panel is moved from its
home position. The GlasStile GSR has acknowledgement outputs that are used when
interfacing with card reader systems. These relay contacts are, by nature, open circuit. They
can be programmed via the Hand Programmer to occur during or after a passage.
When rotation has completed and the gate is locked, the closed gate lamp comes on.
If Acknowledgement A (after rotation) is selected from the programming options, once the
rotation is completed another signal may be given from the impulse unit.
If Acknowledgement D (during rotation) is selected from the programming options then signals
may be given to the unit during a rotation, a maximum of five of these signals can be stacked.
Reset
The alarm period lasts for a period of 20 seconds, the unit‟s blocking panel will then return to the
correct position and normal operation is commenced.
Unauthorised passage
When the gate is locked, the electro-magnetic brake is activated on full power for 0.5 second.
The power is then reduced to a steady rate. This is to reduce the risk of heat build up in the
brake.
When unauthorised passage through the GlasStile GSR is attempted the braking power is less
than 240Nm, but when the lock is disturbed, the brake moves from its steady power rate to
maximum power for 5 minutes before returning to the steady rate.
Blocking or forcing GlasStile GSR during rotation
If the GlasStile GSR is blocked completely during operation for more than 10 seconds, the unit
will go into alarm mode and then commence the reset cycle detailed above.
The maximum force exerted by a unit at its highest speed during opening or closing is
45.6 Newton‟s.
The maximum force needed to break the force of the break when it is locked is 312.8
Newton‟s.
Power Failure
In the event of power failure, the brake will release & the gate will rotate freely. When the power
returns the gate searches first for its internal zero position and then for the home position similar
to when the GlasStile GSR is first started.
Fire Alarm
The GlasStile GSR has a facility for an external fire alarm input. The fire alarm output should be
a
normally closed voltage free (0V) pair
. When this pair is open the unit will freewheel in both
directions, this continues until the input is re-closed.