65
RadaScan Sensor Serial No.
Type
2
Marine Processor
Serial No.
Shipping Line
Vessel Name
Installer
Mechanical Installation
Check
Requirement
9
Sensor
The sensor is mounted securely with 4 bolts.
The sensor’s connection panel is facing away from the operating area.
The sensor has a clear line of sight in the direction of the responder.
The sensor is positioned away from X-Band and S-Band radars, Artemis systems
and other antenna systems (VHF, UHF etc.).
All lifting eyes have been removed and stored away.
Cables
The cables are installed away from power cables.
The cables are properly secured.
Type
2
Marine
Processor
The Marine Processor is mounted securely in an optimum location.
Sensor Connections
Check
Requirement
9
General
All cable shields are correctly earthed.
Power
The sensor’s power inlet is connected correctly to the vessel’s UPS.
Power supply is within the range for the type of sensor that is mounted.
Heater Cable
Ensure heater cable with the required rating is connected correctly to the vessel’s
Emergency Breaker Box.
DP
F
eed
The sensor is connected correctly to the DP system using the approved cables and
connectors.
RadaScan
Dashboard
The sensor is connected correctly to the RadaScan Marine Processor using the
approved cables and connectors.
Dashboard Configuration
Check
Requirement
9
Dashboard record of
Sensor IP Address
The
SensorIP
setting (within the config.ini file, located in the Dashboard’s
installation directory) matches the sensor’s IP address. This can be checked on
the Dashboard by navigating to
More >> Page
2
>> Comms Settings
.
Dashboard Date and
Time
The RadaScan Marine Processor’s Date and Time are set correctly.
ID / Version Info
The sensor’s serial number is shown correctly.
The sensor and Dashboard software version details are correct.
Communications /
Display Options
The DP Message Format and DP Feed Behaviour are set correctly for the
vessel’s DP system.
The Bow Orientation is set correctly.
If the Marine Processor dœs not have a physical keyboard,
the on-screen keyboard is enabled.
Logging is enabled.
Vessel Parameters
The vessel dimensions have been entered correctly.
The Bow and Starboard Offsets have been set correctly.
The Bearing Offset has been set correctly.
Blanking Zone
A blanking zone has been set to cover any superstructure in close proximity to
the sensor.
Disk Space
There is enough free space to accommodate Dashboard data logging.
PDF Reader
Click on the
Help
button and check that the RadaScan Operator’s Guide can
be viewed. If not, ensure that a PDF reader is installed.
Exit Service Access
Mode
The Engineer’s USB key has been removed and the system has been
restarted.
Alarms
No Warning, Error or Fatal alarms have been raised by the system.
Installation Checklist
Network IP
Address
X-Band radar