Blanking Zone
A Blanking Zone can be used to mask the segment of the scan rotation that is obscured by the
vessel’s superstructure. The start and end of the zone can be set to any positions around the circle
to the nearest degree.
Generally, once the blanking zone has been set, it will not need to be changed. However, there
may be occasions when it is necessary to adjust the blanking zone, for example if the responder is
on the opposite side of the vessel to normal.
!
The option to change the blanking zone
is not available whilst tracking.
To Define a Blanking Zone
1. Ensure that the Dashboard is in
Master Mode
.
2. Enter
Service Access Mode (see page 39)
3. Click on
More >> Blanking Zones
.
4. Click on
Show Handles
.
5. Click one of the blanking zone handles on the BEV and, holding down the left mouse button,
drag to the desired position. Alternatively - on a touchscreen - touch and drag. As the handle
is moved, its current position (in degrees clockwise from the vessel bow) is displayed in blue
numerals outside the perimeter of the circle.
6. If required, drag the second zone handle in the same way.
7. The Apply-Cancel buttons will have popped up after step 5. Click on the
Apply
button to set
the blanking zone, or on
Cancel
to restore the blanking zone to its previous state.