l
46
Emergency Breaker Box
DP Instrument Room
Bridge
Mast
Ethernet
Sensor Power
RS-422 Data
Power Cable
P/N 33-0121-3 (40m)
Data Cable
P/N 33-0122-3 (40m)
Ethernet Cable
P/N 33-0124-3 (40m)
16A
5A
5A
DP System UPS
DP System 1
Interface Cabinet
CyScan
Sensor
CyScan Client Computer
Link
Cable
CyScan Client
DP Feed
Power
Ethernet Client, Dual Serial DP
CyScan
Monitor
Monitor Power Cable
Monitor Cable
DP System 2
Interface Cabinet
RS-422 Data
Data Cable
P/N 33-0122-3 (40m)
Cable Routing Diagrams (Continued)
Power
Adaptor
Marine Processor
Power Cable
Note:
The Ethernet cable connecting
the CyScan Sensor to the Type 2 Marine
Processor should not exceed
90 metres
in length.
Please contact Guidance Marine if longer
distances are required.
See page 49 for processor and monitor options
Summary of Contents for CyScan