Provision of the guarantee
Entitlement on provision of the guarantee according to the
enclosed guarantee card.
General Safety Instructions
Read carefully the whole Operation Manual before first use of
the device. If there are any doubts about the connection and
operation of the device, contact the manufacturer (service
department).
OBSERVE CAREFULLY FOLLOWING INSTRUCTIONS SO
THAT THE HIGH SAFETY LEVEL MAY BE GUARANTEED:
Caution: The operation is permitted only with
protection switch against insufficient current (maximum
insufficient current 30 mA according to VDE regulation
part 702). Please consult your electrician-specialist.
The pump shall never be used as a circulating pump in
swimming pools.
Attention: Principally make sure the cooling of the engine is
optimal. Minimum distance from the fan grid should always be
at least 40 cm. Never cover the pump and/or never install it
into a tight shift. Ensure good removal of operation heat.
The pump is not suitable for swimming pools. Electric
installation may be performed only by a specialist. The pump
shall be supplied through installation of a device protecting it
against insufficient current.
Do not allow the pump to be operated without water and
without water supply. Otherwise the pump service life will be
endangered and the engine may be damaged..
Never envelop the pump head engine with a blanket or a
scarf to prevent freezing of water in cold weather.
Do not use pump at outside temperatures over 40 °C or under
0 °C and with water temperature over 35 °C.
The pump shall never be used for other liquids than water.
Do not use sand containing water, the sand may destroy
sealing.
Read carefully Operation Manual before installation and
putting into operation. The persons not acquainted with the
pump operation should carefully read the relevant Operating
Manual for operation and maintenance before putting the
pump into operation, in order to prevent damaging the pump
from the very beginning.
The user is responsible for third persons on the workplace.
The pump may be put into operation exclusively with a cable
or rubber electric extension cord type H07RNF, according to
standard DIN 57282 or DIN 57245.
The pump shall not be lifted, transported or fixed by pulling
the electric connecting cable.
Should cable or a plug be damaged due to external impacts,
the cable shall not be repaired! The cable shall be replaced
by a new cable.
This work may be performed only by an electrician-specialist.
Make sure that the connecting lines to electric sockets are
protected against flooding and moisture.
It is necessary to check before use if the connecting cable
and electric plug are in order. The pump shall be placed on
flat, stabile and horizontal plane.
Pull the plug out of the socket before any work.
The user is responsible for observation of local regulations
related to safety and built-in system.
Before every use check the device visually. Do not use the
device if the safety equipments are damaged or worn out.
Never put the safety equipment out of operation.
The device shall be used exclusively for the purpose given in
thie Operation Manual.
You are responsible for safety in the working region.
If the pump is faulty, the repair shall be performed exclusively
in the repair shops authorized to do so. Only original spare
parts may be used
It is necessary to take relevant measures for preventing the
placing of the device within the reach of children.
Before putting into operation it is necessary to find out by a
professional test if all required electric protection measures
are available.
During operation of home water station nobody may stay in
the medium being repumped.
Prevent the home water station to be exposed to direct water
current.
The owner is responsible for observation of safety provisions
and of provisions for built-in system.
(Consult the electrician-specialist, if necessary)
The follow-up damages due to flooding of the room during
failure of home water station shall be excluded by the user by
taking suitable measures (e.g. installation of alarm equipment,
installation of a spare pump etc.).
Home water station shall never run without water, in case of
damage of home power station due to running without water
the manufacturer´s guarantee expires.
Electrical safety:
DANGER! Electric shock!
Danger of electric current accident!
●
Pull the plug out of the network before filling, after
putting out of the operation, when repairing the failures.
Operation is permitted only on connecting lines
furnished with the insufficient current switch (PRCD)!
●
Please ask the electrician-specialist.
The data on the type label shall comply with the electric
network data.
Protect the cable against heat, oil and sharp edges.
For Austria
The electric connecting line in Austria shall comply with the
ÖVE-EM 42, T2 (2000)/1979 § 22 pursuant to 2022.1.
According to this regulation the pumps may be operated for
use in swimming pools and garden lakes only via separating
transformer.
●
Please consult your electric professional company.
For Switzerland
In Switzerland the devices used outside are different in
various locations, and shall be connected via insufficient
current protection switch.
General Instructions:
●
Before every use perform visual inspection to make sure
that the pump, particularly the network cable and the plug are
not damaged.
A damaged pump shall not be used.
●
In case of a failure the pump shall be checked by the GÜDE
Service or by an authorized electrician-specialist.
Do not expose the pump to rain and do not operate it in wet or
moist environment. The pump must not work without water,
therefore make sure that the end of the suction hose is
permanently in the medium to be repumped.
●
Before every putting into operation the pump shall be filled
with the liquid to be repumped up to the overflow!
When pump is used for supplying the water in a house, the
local regulations of authorities for water and waste water
management shall be observed.
The provisions of DIN 1988 shall also be observed.
What to do in Emergency?
Introduce reasonable first aid measures as necessary
according to the injury, and ask for qualified medical help as
soon as possible.
Secure the injured against any other damage and secure
resting conditions for him.
Use in accordance with the Conditions
The home water station is designated exclusively for pumping
clean water for the purpose or water supply in the house, in
the garden, in the courtyard and in agriculture. Should the
provisions of generally applicable regulations and provisions
in this Manual be not observed, the manufacturer cannot be
responsible for damages.
13