GB
Read this instruction for use carefully before putting the equipment in use.
A.V. 2 Surplus prints (including partial ones) require approval. Technical changes are reserved. Pictures just for Illustrational
purpose!
GB
Do you have any
technical questions?
Complaints?
Do you need spare parts or instructions for use?
We will help you quickly and in non-bureaucratic way in our web page
www.guede.com
in the
Service
section. Please help us helping you. To
allow the identification of your machine in case of any complaint, we need the serial number, order number and the year of production. All the
above data can be found at the rating plate. In order to have the data always ready at hand please write them below.
Serial number: Order number: Year of production:
Tel.:
+49 (0) 79 04 / 700-360
Fax:
+49 (0) 79 04 / 700-51999
E-Mail: [email protected]
Machine
Compressor 250/10/50V
Stationary compressor not requiring much space.
Accessories
(standard):
Pressure sw itch, pressure gauge, pressure reducing valve,
safety valve, mud discharge valve, non-return valve, air filter,
relief valve, bantam w heels, panel made of high-grade steel.
Areas of use:
Suitable for lighter to medium-heavy pneumatic w orks – e.g.
nailing, clipping, cutting, drilling and blasting up to small
painting w orks.
Machine description (Fig. 1)
1.
Air receiver
2.
Carriage
3.
Mud discharge valve
4.
Rubber foot
5.
Handgrip adjustment
6.
Pressure reducing valve
7.
Overpressure valve
8.
Air pressure gauge in the receiver
9.
Air filter
10.
Handgrip for carrying
11.
Output pressure gauge
12.
Quick couplers
13.
Oil stopper
14.
Pressure sw itch
15.
Inspection sight
16.
Screw for discharging the oil
Warranty
The guarantee solely covers inadequacies caused by material
defect or manufacturing defect.
Original payment voucher w ith the sales date needs to be
submitted for any claim in the guarantee period.
The guarantee does not cover any unauthorised use such as
appliance overloading, use of violence, damage as a result of
any unauthorised interference or caused by foreign items.
Failing to follow the operating and assembly instructions and
common w ear are also not included in the guarantee.
General safety instructions
The instructions for use should be read completely before the
first use of the machine. If any doubts regarding connection
and/or operation of the machine please contact the producer
(service department).
Instructions for installation
•
Check the machine for any damages suffered during
transport.
•
Any damages should be immediately claimed to the
carrier w ho delivered the compressor.
•
The oil level in the compressor's pump should be
checked before putting into operation.
•
The compressor must be installed close to the
consuming appliance.
•
Long air pipes and long feeding cables (extension
cables) are not recommended.
•
Pay attention to keeping the suction air clean and free of
dust.
•
Do not install the compressor in a humid or w et room.
•
The compressor may be used only in suitable rooms
(w ell ventilated, ambient tempe5°C to 40°C). In
the room no dust, acids, vapours, explosive or
flammable gases may be present.
•
The compressor is suitable for use in dry rooms. The
use of the compressor in places w here splashing w ater
is used the use of the compressor is not permitted.
IN ORDER TO GUARANTEE THE HIGH LEVEL OF
SAFETY THE FOLLOWING INSTRUCTIONS SHOULD BE
OBSERVED WITH CARE:
The machine meets the requirements of EN 61000-3-11 and is
subject to special conditions for connection. It means that its use in
arbitrarily selected points of connection is not allow ed.
The machine could cause transient voltage fluctuation in case of
inconvenient conditions of the mains.
The machine is intended exclusively for use in point of connection
not exceeding the maximum admissible impedance of the mains
Z
max
= 0,23
3 Ω.
You as a user are obliged to ensure or possibly after
arrangement w ith your electrical energy supplier that your
connection point w here you w ant use to operate the machine
meets the requirement specified above.
Attention: Use only with the RCD (protective switch
avoiding the stray current)!
•
Do not leave the machine unattended
•
Do not leave the machine switched on unattended
because it could become a source of risks!
•
Always switch the compressor off using the
pressure switch, pull the plug out of the wall socket
and empty the air receiver!
•
Keep the workplace clean and tidy.
Disorder at the
w orkplace and w ork table increases the risk of accidents
and injuries.
•
Pay attention to the environmental conditions where
you are working.
Do not use electric equipment and
tools in humid and w et environment. Ensure sufficient
lighting. Do not expose electric tools to rain or high air
humidity. Do not sw itch electric equipment on in the
vicinity of flammable liquids or gases.
•
Do not allow unauthorized persons to access to the
machine.
Visitors and bystanders, especially children
and sick or w eak persons should be kept in a safe
distance from your w orkplace.
•
Ensure safe deposition of tools.
Store all machines
that you are not using, into a dry place, preferably in
height or lock them so that they are not accessible for
other persons.
•
Always use a proper machine for ever work.
Do not
use for instance small machines or accessories for
w orks that are actually to be done using large machines.
Summary of Contents for 50066
Page 2: ...1 1 14 12 1 10 15 13 8 7 16 6 5 2 3 4 9 2 3 ...
Page 3: ......
Page 66: ......
Page 67: ......