PX Control Panel User Manual – Issue C
- 34
-
Event log only messages
Log Text
Additional Data
Display Text
Event Description
Knock
Circuit
nnn
Cct
nnn
Circuit first knock
Line Block
NONE
NONE
SmartDial has reported a line
blocked condition
Line Fault
1 - 50 volts not present
2 - Line block test failure
3 - No acknowledge from
central station
4 - Main PCB LF input
5- SmartDial Fault
NONE
Communicator has reported a
line fault
Lockout
Keypad
n
KP
n
Incorrect code attempt limit
reached on the keypad
Logged Off
User
nn
, Keypad
m
Us
nn
, KP
m
User logged off keypad
Logged On
User
nn
, Keypad
m
Us
nn
, KP
m
User logged on keypad
Managed Rst
Keypad
m
KP
m
Managed reset code entered
Marginal
Circuit
nnn
Cct
nnn
A Circuit is marginal
Mult. Alarm
Circuit
nnn
Cct
nnn
Circuit has alarmed up to the
multiple alarm limit
Normal
User
nn
, Conc
m
Us
nn
,
m
Isolate removed from a
concentrator
Normal
User
nn
, Circuit
mmm
Us
nn
Cct
mmm
Bypass or isolate removed from a
circuit
PC Access
User
00
Us
nn
A GSR user has logged on
remotely.
Power Fail
NONE (see note)
NONE
Supply voltage has
fallen to the power fail threshold
Pre-Warning
Circuit
nnn
Cct
nnn
A circuit has been alarmed during
the entry period
Reprogrammed
User
nn
, Keypad
m
Us
nn
, KP
m
A configuration option(s) has
been changed
Reset
Circuit
nnn
Cct
nnn
An area has been reset
Reset
User
nn
, Area
m
Us
nn
, Us
nn
An area has been reset
Clear
Circuit
nnn
Cct
nnn
A Circuit alarm has cleared.
Restored Code(s)
User
nn
, Keypad
m
Us
nn
, KP
m
All codes have been restored to
default
Set
User
nn
, Area
m
Us
nn
A
m
Area has been set by a user
Shunt Off
Circuit
nnn
Cct
nnn
A master shunt circuit or the
event programmer schedule has
removed the shunt from a circuit
Shunt On
Circuit
nnn
Cct
nnn
A master shunt circuit or the
event programmer schedule has
shunted a circuit
Soak Alarm
Circuit
nnn
Cct
nnn
A circuit on soak test has
alarmed
Soak Failed
Circuit
nnn
Cct
nnn
At the end of the soak period any
circuit which has alarmed is
logged as failed
Soak Off
Circuit
nnn
Cct
nnn
A circuit has been taken off soak
Soak On
Circuit
nnn
Cct
nnn
A circuit has been put on soak
Software Error
N
N
A software error has been logged
Temp Bypass
Circuit
nnn
Cct
nnn
A circuit has been temporarily
(until clear) bypassed
TX On
N
N
TX channel N on
TX Off
N
N
TX channel N off
Unset
User
nn
, Area
m
Us
nn
A
m
A user has unset the area