PX Control Panel User Manual – Issue C
- 14
-
Message
Reason
Alarm Abort
User logs on within the alarm abort period (programmable option)
Setting Stopped
User logs on during the setting exit period
Group Unset
A group(s) is set and is programmed to automatically unset when a user logs on.
Cannot Set
The system cannot set, the reason(s) will then be displayed.
Unset Alarm
An unset alarm has occurred, the details will then be displayed.
Mult.Alarm
A circuit(s) has alarmed the maximum number of times allowed (programmable).
The circuit details will then be displayed.
Code Known
Another user has chosen your code. You will then be given the option of
immediately changing your code. This message will always be displayed on log
on until the code is changed.
Call Engineer
You should call the installation company. The details will then be displayed.
Reset OK
A managed reset code has been accepted
Set
4
=Confirm
The user is configured for the log on set option. If confirmed the system will start
setting (if only one group is authorised) or display the set group menu.
Soak Cct Fails
Circuits which have been put on special test by the installation engineer have
alarmed.
Dual User Code Operation
Where a higher level of security is required a keypad may have been programmed to require two user
codes to be entered before logging a user on to the system. Both user codes must be authorised and
are logged by the system. The authority of the second user code entered is used by the system.
Unset
Code-01
The system will have been partitioned by the installation engineer into a number of set groups. The user
authority will determine the choice of groups, which can be unset. There are several methods of
unsetting available to the user. These methods are discussed in the following section.
Unsetting Methods
If a set group incorporates an entry route in the unsetting procedure then opening a final entry door to
the area will start a pre-programmed entry timer. The user must proceed directly to the keypad or
keyswitch via a pre-determined entry route and unset the group as described.
If the group is not unset before the entry time has expired a warning period, equivalent to 50% of the
programmed entry time, will be allowed. This is to warn the user that an alarm condition will occur if the
group is not unset by the end of the warning period. If the group is not unset by the time that the total
entry time and warning time has expired, an alarm condition will be initiated.
During the entry time, if a user deviates from the prescribed entry route into an armed area, the entry
time is immediately cancelled. If programmed, a fixed pre-warning period of 45 seconds will be given,
otherwise an immediate alarm will be given. If the user enters an armed area during the entry warning
period, the warning period is cancelled and an immediate alarm will be given.
Unsetting from a keypad
To unset, log on to the keypad. If an authorised group is configured for automatic logon/unset then the
unset group descriptor will be displayed.
Workshop
Unset
If more than 1 group is configured for logon/unset then only the first
descriptor will be displayed.
Intelligent Security & Fire Ltd