background image

Guardall Limited

Lochend Industrial Estate

Newbridge

Edinburgh EH28 8PL

Tel: 0131-333-2900

FAX: 0131-333-4919

Technical Hotline: 0131-333-3802

Part Number: 320680-0C

Intelligent Security & Fire Ltd

Summary of Contents for PX18

Page 1: ...PX Control Panel User Manual Issue C I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 2: ...TE 11 MENU RESTRICTIONS 11 LOGGING OFF 12 HELP 13 Remote Service 13 Contract 13 Product Info 13 KEYPAD BACKLIGHT 13 LOG ON MESSAGES 13 DUAL USER CODE OPERATION 14 UNSET 14 UNSETTING METHODS 14 Unsetting from a keypad 14 Unsetting from a keyswitch 16 Automatic Unsetting 16 UNSETTING WARNINGS 16 UNSETTING AFTER AN ALARM 16 SET 17 SETTING FROM A KEYPAD 17 KEYSWITCH SETTING 17 AUTOMATIC SETTING 18 Abo...

Page 3: ... PX80 500 28 DOOR ACCESS PX80 500 28 Challenged 28 LOCKOUT PX80 500 28 EXPIRY DATE PX80 500 28 LOGS 30 EVENT LOG MESSAGES 30 PRINTED LOG 30 LOG FULL 31 LOG CCT 31 LOG USER 31 LOG KP 31 LOG DATE 31 LOG ALARM 31 A LOG FULL 31 A LOG USER 31 A LOG DOOR 31 LOG MESSAGES 32 TIME 36 HOLIDAY 37 START 37 END 37 SET GROUP PX80 500 37 SET GROUP 1 8 PX34 37 SCHEDULE PX18 34 38 SCHEDULE 38 START TIME 38 STOP TI...

Page 4: ...T 41 PRINT HOLS 41 ACCESS FEATURES 42 SECURITY SYSTEM INTEGRATION 42 ADD USER 43 DELETE USER 43 IDENTIFY USER 43 DOOR UNLOCK 43 DOOR LOCKOUT 44 DOOR TEXT 44 ISOLATE CCT 44 ISOLATE CONC 44 CCT STATUS 45 SYSTEM DETAILS 46 KEYPADS 46 SET GROUPS 46 CIRCUITS 48 USERS 50 I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 5: ... automatically removed when the next event occurs All log events are date and time stamped and may be viewed or printed if a printer is fitted to the system Areas Set Groups For protection purposes the premises may be divided into a number of areas Individual areas may be grouped together into a setting group which provides the user with a convenient way of setting and unsetting more than one area...

Page 6: ...y interface Throughout this manual user codes are only referred to as codes Operator Controls and Displays System Keypads 2 x 16 character LCD backlit display Mains indicator Optional electronic key socket The operator keypad unit incorporates a backlit liquid crystal display LCD comprising 2 lines of 16 characters and a backlit keypad to gain access to the system and to perform all authorised use...

Page 7: ...and duplicate tokens cannot be obtained Spare or replacement tokens can be obtained from the installation company Keyswitch As an alternative method of setting and unsetting a simple On Off keyswitch may be fitted to the system Using the System When no user is logged on to a keypad the time date and company will normally be displayed 12 00 Mon 27 Sep Guardall The LCD keypad will normally display t...

Page 8: ...n and the current system status Only 2 options will be visible on the display but all available options can be selected by entering the 2 digit code without viewing the actual option number 16 A Log Full 17 A Log User 18 A Log Door 20 Time 24 Holiday 25 Schedule 26 SetGroup 30 Bypass 31 KP Off 32 Chime 40 Print Text 42 Print Hols 50 Add User 51 Delete User 52 Identify User 53 Door Unlock 54 Door L...

Page 9: ...mber __ 01 04 05 30 32 24 20 02 1 Sounder 2 Audio 3 Strobe 4 Walk Test 5 Comms Test 1 Silent Set 2 Instant Set 07 New Code Enter 06 11 User Number __ 12 17 10 15 16 Keypad Number _ 13 Filter Date EnterDDMMYYYY 14 Holiday 1 Start Off End Off Set Group 00 Keypad Number _ 31 Printing Text Printing Holiday 42 40 Schedule Number __ 25 Schedule n Start Time 00 00 Stop Time 00 00 Mon Off Tue Off Wed Off ...

Page 10: ...be 4 Walk Test 5 Comms Test 1 Silent Set 2 Instant Set 07 New Code Enter 06 11 User Number ____ 12 17 10 15 16 Keypad Number __ 13 Filter Date EnterDDMMYYYY 14 Holiday 1 Start Off End Off Set Group 00 Keypad Number _ 31 Printing Text Printing Holiday 42 40 Schedule Number __ 25 User xx Descriptor Manager Code Change On LogOn Set On Group 1 Off Group 2 Off Group 32 Off 3 1 Mon 2 Tue 3 Wed 4 Thu 5 F...

Page 11: ...herwise they will be automatically logged off Engineer On Site Engineer Out Of Service When an engineer logs on to a keypad all other keypads in the system will be inoperable and the display will show Out of Service Menu Restrictions If a menu number is entered and the option is not available then a reason will be displayed For example if no area is set and you select unset the panel will prompt w...

Page 12: ...is unset for example the event log Unset Area User attempts to unset an unset area Key Not Used The key button which has been pressed is never used in the current menu Printer Busy User attempts to print and the printer is in use Not Programmed The option selected is not programmed Keypad Busy User attempts to turn off a keypad that is being used Not Applicable User attempts for example to reset w...

Page 13: ...l then be able to check the condition of your system and identify and resolve problems Help Menu Contract The contract number uniquely identifies the system Contract 123456 The customer contract number is a 6 digit number programmed by the installation engineer Help Menu Product Info W73797 v1 00 The panel order code and firmware version number S Dial v4 0x The SmartDial version number if fitted P...

Page 14: ...he system will have been partitioned by the installation engineer into a number of set groups The user authority will determine the choice of groups which can be unset There are several methods of unsetting available to the user These methods are discussed in the following section Unsetting Methods If a set group incorporates an entry route in the unsetting procedure then opening a final entry doo...

Page 15: ...PX Control Panel User Manual Issue C 15 If automatic logon unset is not configured then choose the unset option manually I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 16: ... When unsetting from a keypad the user is informed on the display of any warnings e g circuits isolated or on soak The warning display will appear for approximately 4 seconds during the unsetting procedure If more than one warning exists the display will automatically scroll through the list of warnings Loading Door Isolated An example of an isolated circuit warning after unsetting Unsetting After...

Page 17: ...its after opening and closing the final exit circuit Setting from a keypad To set log on and select the set option 02 Set 05 Eng Press 02 to set If more than 1 authorised group is unset then the available groups will be displayed 1 Workshop 2 Office Choose the group to set Workshop Setting The setting message will be displayed Workshop Seconds Left 005 If timed setting is configured for the group ...

Page 18: ...normal way The user however may wish to change a condition before setting the area s or system where appropriate When a user selects set and warnings exist the set warning prompt will be displayed Set Warning 4 Report Press the 4 button to display the setting warning s Loading Door Isolated The display will automatically scroll through the list of warnings Workshop 4 Set Press 4 to proceed with se...

Page 19: ... to confirm setting Failure to Set after Exit Time If the group fails to set at the end of the exit period the exit tone will change to warn the user that the system has not set Log on to the keypad to display the fault condition s The external sounder may also have been programmed by the installation engineer to activate in the event of a failure to set I n t e l l i g e n t S e c u r i t y F i r...

Page 20: ... If an alarm condition cannot be reset then a message will be displayed Engineer Reset If the system is configured for engineer reset then after the alarm s information is displayed a special prompt will be displayed 01313333802 Code 123456 The number to call for a service engineer Quote your customer contract number When an engineer reset is required it will not be possible to set the system unti...

Page 21: ...ser presses the 7button Test Options Strobe Code 2 The external strobe s will be turned on until the user presses the 7button Test Options Audio Code 3 The internal sounder s will be turned on until the user presses the 7button Test Options Walk Test Code 4 The panel records all activations from sensors during the unset period When walk test is selected the panel will display all circuits which ha...

Page 22: ...PX Control Panel User Manual Issue C 22 All Tested I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 23: ...ximity token To change user code log on to the keypad using your current code and choose the code option Then follow the display prompts All user code changes are recorded in the system event log Note If the code option is not available this means that the system has been programmed to prevent you from changing your user code and a new code must be allocated by the security system manager New Code...

Page 24: ... available on the PX18 34 User Name Code 1 When the name option is selected the current user descriptor will be displayed Names can be up to 10 characters long and may contain any of the following characters ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz _0123456789 By default all names are User followed by the user number for example User 2 User Number 03 J Smith The first character of the ...

Page 25: ...nn User number User Name Manager Press for list of user authorities Code Change On On Off LogOn Set On On Off Schedule 1 Off On Off PX18 34 only Schedule 2 Off On Off PX18 34 only Group 1 Off On Off Group 2 Off On Off Group 32 Off On Off the number of groups depends on the panel type On Off PX18 34 only Door 1 Off Door 2 Off On Off PX18 34 only The available menu options are dependent on the progr...

Page 26: ... 7 7 7 32 Chime 3 3 7 7 7 7 7 7 7 40 Print Text 3 7 7 7 7 7 7 7 7 42 Print Hols 3 7 7 7 7 7 7 7 7 50 Add User 3 7 7 7 7 7 7 7 7 51 Delete User 3 7 7 7 7 7 7 7 7 52 IdentifyUser 3 7 7 7 7 7 7 7 7 53 Door Unlock 3 7 7 7 7 7 7 7 7 54 Door Lockout 3 7 7 7 7 7 7 7 7 55 Door Text 3 7 7 7 7 7 7 7 7 71 Copy User 3 7 7 7 7 7 7 7 7 73 Copy A User 3 7 7 7 7 7 7 7 7 86 Isolate Cct 5 7 7 7 7 7 7 7 7 87 Isolate...

Page 27: ...PX Control Panel User Manual Issue C 27 displayed when logging on or if there is only one set group available setting will start when the user logs on I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 28: ...Door Access PX80 500 Code 5 Each user can be programmed for any combination of the available doors User Options User nnnn nnnn User number Enable Off On Off this option must be on to view other options Door 1 Off On Off Door 32 Off On Off Challenged Off On Off Door Options Challenged On Off If a user is programmed as challenged then the door release and open times will be automatically doubled for...

Page 29: ...PX Control Panel User Manual Issue C 29 Off No expiry date is programmed press enter to change I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 30: ...nformation specified by the event type Each event is time stamped to the nearest 2 seconds If a text description has been programmed it will be used in the printed log When the log is displayed abbreviations are used The displayed log format is PIR in Hall the circuit description Bypassed the event type The event time and circuit number may be displayed in place of the normal top line information ...

Page 31: ... All logged alarm events may be displayed or printed Access Log A Log Full Code 16 The access log capacity of the system is 1000 events This log contains the most recent 1000 events for all doors in chronological order All log options are configurable for each door The Access log options are only accessible to users with manager authority The full access log may be displayed or printed Access Log ...

Page 32: ...ntrol panel comm fail input active Entry Alarm Area n An The area is not unset before the end of the entry warning period Fire Circuit nnn Cctnnn A fire type circuit alarm Panel Tamper NONE NONE Panel case or off the wall tamper Personal Attack Circuit nnn Cctnnn A PA type circuit alarm Rmt Auth Fail NONE NONE Repeated attempt to log on by a remote host Sndr Tamper NONE NONE Panel sounder tamper T...

Page 33: ...pe circuit clears Code Clash User nn User mm Usnn Usmm User has chosen a new code which is the same as another user Comm Acknowledge n N Central station acknowledge alarm report Comm Fail n N Central station fails to acknowledges alarm report Comm Test User nn Keypad m Usnn KPm User or the panel tested the communicator s Duress Alarm User nn Keypad m Usnn KPm User enters a duress code Engineer Res...

Page 34: ...Pre Warning Circuit nnn Cctnnn A circuit has been alarmed during the entry period Reprogrammed User nn Keypad m Usnn KPm A configuration option s has been changed Reset Circuit nnn Cctnnn An area has been reset Reset User nn Area m Usnn Usnn An area has been reset Clear Circuit nnn Cctnnn A Circuit alarm has cleared Restored Code s User nn Keypad m Usnn KPm All codes have been restored to default ...

Page 35: ...ue C 35 Event log only messages Log Text Additional Data Display Text Event Description Verify Alm Area n An A verified alarm has occurred Watchdog NONE NONE Software watchdog active I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 36: ...Door m Usnn Doorm User request to set from door m Unset Req User nn Door m Usnn Doorm User request to unset from door m Exit User nn Door m Usnn Doorm User exit by door m Door Open Door m Doorm Door held open Forced Door m Doorm Door forced open Unlock Door m Doorm Door unlocked Lock Door m Doorm Door lock Pending Door m Doorm Schedule unlock pending RTE Door m Doorm Door RTE button active Time Co...

Page 37: ... it is removed from the holiday schedule It is not possible to program a holiday period that starts in December and ends in January To achieve this 2 holiday periods must be programmed Holiday Menu Start DD MM Enter the holiday start day and month To disable a holiday enter a date of 00 00 The date entered must be before the programmed end date Holiday Menu End DD MM Enter the holiday end day and ...

Page 38: ...Mon Off On Off Tue Off On Off Sun Off On Off Holiday Off On Off Schedule Menu Start Time HH MM To disable a schedule the start and stop times should be set to 00 00 Schedule Menu Stop Time HH MM To disable a schedule the start and stop times should be set to 00 00 Schedule Menu Mon Sun On Off Each schedule can be configured for any combination of days if the start or stop times are non zero The pr...

Page 39: ...d 4 Thu 5 Fri 6 Sat 7 Sun 8 Hol Select the day or holiday Hol to program the schedule times Schedule Options Schedule nn Day nn Schedule number Day selected day or holiday Start 1 00 00 HH MM Stop 1 00 00 HH MM Start 2 00 00 HH MM Stop 2 00 00 HH MM Two sets of times may be programmed for each schedule day This allows for example 2 access periods to be configured for a user or 2 auto set unset tim...

Page 40: ...31 A keypad can be disabled by an authorised user if required Disabling a keypad will render all buttons on the keypad inoperative however the keypad display will continue to operate normally To disable a keypad enter the keypad number Keypad x On Press 0 to turn off or 1 to turn on 12 00 Mon 27 Sep Out of Service A keypad that is turned off will show the time date and out of service message Not A...

Page 41: ...t Text Code 40 The print text option will print all text descriptors for users circuits set groups and the company name Printing Print Hols Code 42 The print holiday option will print all holiday periods I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 42: ...d user 1 is always the engineer The PX access control system can be configured through a security system keypad or a PC running GuardStation Access Guardall PX proximity tokens may only be introduced to the system through a PX keypad with an integrated proximity reader The Access Module door input may be programmed as a circuit Refer to the Input Map option for details Access System Security Syste...

Page 43: ...dentify User Code 52 This option allows a user to be identified by presenting the card fob Present Card Fob Present the token or press 7to exit If the card fob is not used then a message will be displayed Code Not Used Present another token or press 7to exit If the token is used then a message will be displayed User X The user number User Descriptor Further card fobs may be presented and identifie...

Page 44: ...he isolate circuit option will only be available if programmed by the installation engineer The isolate circuit operation enables a circuit to be isolated in case of a fault When isolated the alarm and tamper condition of a circuit are ignored Circuit Number x Enter the circuit number Circuit x Normal The current state will be displayed When a circuit is isolated it is ignored until the isolate is...

Page 45: ...C 45 Cct Status Code 89 The circuits that are on soak bypassed or isolated can be displayed Cct Status Normal The display will scroll all circuits that are bypassed isolated or shunted I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 46: ...Number of Areas Number of keypads Number of Circuits Number of Users Service Number Contract Number Keypads Number Location 1 2 3 4 5 6 7 8 Set Groups Areas Number Description 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 47: ...PX Control Panel User Manual Issue C 47 Areas Number Description 1 2 3 4 5 6 7 8 8 I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 48: ...cuits Number Description Location Cct 1 Cct 2 Cct 3 Cct 4 Cct 5 Cct 6 Cct 7 Cct 8 Cct 9 Cct 10 Cct 11 Cct 12 Cct 13 Cct 14 Cct 15 Cct 16 Cct 17 Cct 18 Cct 19 Cct 20 Cct 21 Cct 22 Cct 23 Cct 24 I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 49: ...PX Control Panel User Manual Issue C 49 Number Description Location Cct 25 Cct 26 Cct 27 Cct 28 Cct 29 Cct 30 Cct 31 Cct 32 Cct 33 Cct 34 I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 50: ...nel User Manual Issue C 50 Users Areas or Set Groups Number Name Authority Level 1 2 3 4 5 6 7 8 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 51: ...PX Control Panel User Manual Issue C 51 Areas or Set Groups Number Name Authority Level 1 2 3 4 5 6 7 8 27 28 29 30 31 32 33 34 35 36 37 38 39 40 I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 52: ...ll Limited Lochend Industrial Estate Newbridge Edinburgh EH28 8PL Tel 0131 333 2900 FAX 0131 333 4919 Technical Hotline 0131 333 3802 Part Number 320680 0C I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Reviews: