PX Control Panel User Manual – Issue C
- 42
-
Access Features
The number of Access Modules that can be connected depends on the panel variant:
Feature
PX18
PX34
PX80
PX500
Access Modules
2
2
16
32
The table shows the access features across the panel range.
Feature
PX18
PX34
PX80
PX500
Doors
2
2
16
32
Panel Users
20
40
100
200
Access Users
20
40
1000
1000
User expiry dates
7
7
3
3
Challenged user option
7
7
3
3
User lock out from keypad
7
7
3
3
Door lock/unlock from keypad
3
3
3
3
Programmable unlock time
3
3
3
3
Programmable Aux. relay time
3
3
3
3
Anti pass back
3
3
3
3
Access log events
1000
1000
1000
1000
Access log real time print
3
3
3
3
Set & unset
3
3
3
3
Note: The panel users must be the first users in the system. For example on the PX 500 users 2-200
may be access or panel users, users 201-1000 can only be access users and user 1 is always the
engineer.
The PX access control system can be configured through a security system keypad or a PC running
GuardStation™ Access. Guardall PX proximity tokens may only be introduced to the system through a
PX keypad with an integrated proximity reader.
The Access Module door input may be programmed as a circuit. Refer to the Input Map option for
details.
Access System
Security System Integration
1. The door contact may be programmed as a security panel entry/exit circuit or be given any other
circuit response.
2. An access system user can be programmed as a security system user.
3. The door may not be unlocked while the access module area is set. The access module area is the
area that the door circuit is programmed for.
4. All doors may be programmed to open if a fire alarm is reported from the security system.
5. The door area may be set and unset from a Proximity reader.
Outputs on the security system may be programmed to follow the state of a door circuit.
Intelligent Security & Fire Ltd