PX Control Panel User Manual – Issue C
- 40
-
Bypass
Code-30
The bypass option will only be available if a circuit(s) has been programmed as bypassable by the
installation engineer.
The bypass circuit option allows the user to bypass a circuit that is in a fault condition. When bypassed
the alarm condition of a circuit is ignored.
Circuit
Number-x
To bypass a circuit select the bypass option from the main menu, followed
by the circuit number.
Circuit -x
Normal
The current state will be displayed
When a circuit is bypassed it is ignored until the bypass is automatically removed when the circuit is
next unset or until a user removes the bypass. All bypass actions are stored in the event log.
A bypass limit will have been programmed by the installation engineer to limit the number of circuits that
can be bypassed at any one time. The system will display an error message if you try to exceed this
limit.
Keypad Off
Code-31
A keypad can be disabled by an authorised user if required. Disabling a keypad will render all buttons
on the keypad inoperative, however the keypad display will continue to operate normally.
To disable a keypad, enter the keypad number.
Keypad-x
On
Press 0 to turn off or 1 to turn on.
12:00 Mon 27 Sep
Out of Service
A keypad that is turned off will show the time/date and out of service
message.
Not Available:
Keypad Busy
You cannot turn off a keypad which is being used. If this is attempted a
warning message will be displayed.
The installation engineer may also have programmed the system to turn off a keypad(s) at various times
of day. This allows, for example, a keypad in a public area to be turned off while the area is unset.
Chime
Code-32
Certain circuit types can be selected as chime circuits when unset.
To select the chime function for a circuit, enter the circuit number.
Circuit -x
The circuit descriptor will be displayed.
Front Door
Press any button to display the current chime status of the circuit.
Circuit -x
Chime-Off
Press 0 to turn off or 1 to turn on.