25
The Roll-Up III
CalComp
Selects CalComp-compatible formats. See Advanced
Programming Information in the Roll-Up III Online Help for greater
detail on CalComp format structure. Choices are: Binary, ASCII 1,
ASCII 2, ASCII 3, or ASCII 4.
Summa
Selects Summagraphics-compatible formats. See Advanced
Programming Information in the Roll-Up III Online Help for greater
detail on Summagraphic format structure. Choices are: Binary, or
ASCII.
ASCII formats can be modified by including, or excluding, a button code,
space, decimal point, carriage return, or line feed, depending on whether
GTCO, CalComp, or Summa formats have been selected.
Button
Defines whether the Pushbutton (Pb) value is included in the
ASCII output report. This option is available only with GTCO formats.
Choices are: Include, or Exclude.
Space
Defines whether the Space (Sp) character (hex 20) is included
in the ASCII output report as a delimiter between the X and Y coordi-
nate values. This option is available only in GTCO formats. Choices
are: Include, or Exclude.
Decimal
Defines whether the period character (hex 2E) is included
in the ASCII output report between the units and tenths digits. This
option is available only in Summagraphics formats. Choices are:
Include, or Exclude.
Return
Defines whether the Carriage Return (CR) character (hex 0D)
is included in the ASCII output report as a terminator. This option is
available in GTCO and Summagraphics formats. Choices are: Include,
or Exclude.
Line Feed
Defines whether the Line Feed (LF) character (hex 0A) is
included in the ASCII output report as a terminator. This option is
available in GTCO, CalComp and Summagraphics formats. Choices
are: Include, or Exclude.
Mode Options
Mode
Defines how output reports are sent from the digitizer.
Choices are: Point, Line, Continuous, Line Incremental, or
Continuous Incremental.
Rate
Determines how fast output reports will be transmitted from
the digitizer. Choices are: 12, 50, or 100 reports per second.
Resolution
The smallest reported value returned by the digitizer.
Choices are: 1000 lpi, 2000 lpi, 4000 lpi, 40 lpmm, 100 lpmm, or 150
lpmm.
See the Advanced Programming Information section in the Roll-Up III
Online Help at www.gtcocalcomp.com for more details.