Geophysical Survey Systems, Inc.
SIR® 20
Manual
MN92-078 Rev F
30
5
This window allows you to set grid size and line spacing. Enter in the appropriate values for your
survey area.
•
If you only want to collect data in one direction, leave a zero in the line spacing box of the
direction (e.g., X or Y) that you do not want to collect.
Figure 28: Grid Geometry Window.
6
Choose your starting point and whether you want to collect data in zigzag fashion or in a single
direction. Click Next > to go to the Configuration window.
Figure 29: Configuration window.
7
This screen controls your collection parameters. Most of the time the default settings will be
adequate. To access settings for different applications click the small arrow in the Config Type (
1
)
option.
•
You will see a broad list of application categories. Select the one that best describes your specific
application.
•
For example, if you are scanning a concrete slab to find reinforcing bars, choose CONCRETE.
Then choose your antenna type under Config Name (
2
). An X after the name is used to denote a
cross-polarized antenna that is used 90 degrees to its normal orientation. Common data collection
parameters will be automatically set.