Chapter 6 Display and Operations
65
Figure 6-8 Operations for Parameter management
Attention
z
It is recommended to perform speed trial operation and JOG operation when the motor is
unloaded in order to prevent the equipment from accident.
z
The drive unit SON (servo enabled) shall be active and the CCW and CW drives enabling
inactive during trial operation.
6.5 Speed Trial operation
First set No.4 parameter “Operation control mode” to “2 – Trial operating mode”, then select “Sr-”
in the first layer and press the Enter key to start the trial operating mode. The prompt for speed trial
operation is “S” and figures are expressed in rpm. When the system is speed control mode, the speed
command is given by keys. Speed commands may be changed using
↑
and
↓
keys so that the motor
operates at given speed. Speed is increased in forward direction when
↑
is pressed and decreased in
reverse direction (increased in reverse direction) when
↓
is pressed. The motor rotates forward when
the indicated speed is positive and reversely when it is negative.
S 800
↑
↓
Figure 6-9 Block diagram of speed trial operation