![GSK DA98E Series User Manual Download Page 60](http://html.mh-extra.com/html/gsk/da98e-series/da98e-series_user-manual_2275234060.webp)
Chapter 5 Alarms and Remedies
51
Overload of the motor
①
.
Reduce the load.
①
Reduce start and stop
②
frequency.
Reduce the torque
③
limit.
Reduce the relevant
④
gain.
Change it with a drive
⑤
unit and motor with
higher power.
The alarm is
given during the
operation of the
motor.
Internal fault of the
①
motor.
Change the
①
servomotor.
The motor i
①
s
mechanically blocked.
Check the mechanical
①
portion of the load.
6
Saturation fault
of speed
amplifier
The alarm is
given during the
operation of the
motor.
Excessive load
①
.
Reduce the load.
①
Replace it with a
②
drive
unit and motor with
higher power.
7
Drive disabling
failure
①
Both CCW and CW
drive disabling input
terminals are open.
Che
①
ck the wiring and
the power supply for the
input terminals.
8
Overflow of the
position
deviation
counter
The motor is
①
mechanically blocked.
Abnormal input
②
command pulse.
Check the mechanical
①
portion of the load.
Check the command
②
pulse.
Check that t
③
he motor
rotates to the command
pulse.
Error in encoder wiring
①
.
Check the wiring.
①
Damaged encoder
①
.
Change the motor.
①
9 Fault
of
encoder
Defective power cable
①
for the encoder.
Change the power
①
cable.