Chapter 5 Alarms and Remedies
55
②
Defective power
cable.
③
Poor cable shielding.
④
Improper connection
of shield earth wire.
⑤
Fault of the encoder
interface circuit.
31
UVW signal
error of
encoder
①
Damage of UVW
signal of encoder.
②
Damage of Z signal
of encoder.
③
Defective power
cable.
④
Poor cable shielding
⑤
Improper connection
of shield earth wire
⑥
Fault of the encoder
interface circuit.
①
Change the encoder.
②
Check the encoder
interface circuit.
32
Illegal encoding
of UVW signal
of encoder
①
Damage of UVW
signal of encoder.
②
Defective power
cable.
③
Poor cable shielding.
④
Improper connection
of shield earth wire.
⑤
Fault of the encoder
interface circuit.
①
Change the encoder.
②
Check the encoder
interface circuit.
33
Abnormality of
bus
communication
①
Loose network cable
and poor contact.
②
Damaged
communication chip
in the control board.
①
Check that the
network cable is
correctly connected.
Otherwise change
the control network
cable.
②
Change the servo
Drive Unit.
Table 5-5 Added Alarms of V3.01and Remedies