![GSK DA98E Series User Manual Download Page 71](http://html.mh-extra.com/html/gsk/da98e-series/da98e-series_user-manual_2275234071.webp)
DA98E Series AC Servo Drive Unit User Manual
62
1)
Parameter Setting on Servo Drive Unit
Select “PA-” in the first layer and press the Enter key to enter the parameter setting mode.
Choose a parameter number using the
↑
and
↓
keys and press the Enter key to indicate the setting of
the parameter. The parameter setting may be modified using the
↑
and
↓
keys. The parameter setting
increases or decreases by one each press of the
↑
or
↓
key. The parameter setting increases or
decreases continuous when the
↑
or
↓
key is pressed and held. Once the parameter setting is
changed, the decimal point on the right LED nixie tube is lit. The change in the setting becomes
effective when the Enter key is pressed. Now the decimal point on the right LED nixie tube goes out
and the changed value is immediately reflected in control. Thereafter it is possible to continue to
modify the parameter setting with the
↑
or
↓
key and then return to the parameter selecting state by
pressing the
←
key. If you are not satisfied with the setting being changed, press the
←
key other
than the Enter key to cancel the setting, restore it to the original value and return to the parameter
setting state.
Figure 6-6 Block diagram of parameter setting
2)
Setting of Parameters on the System
After start, first check the drive unit parameters saved in CNC system and servo are consistent (The
system gives the relevant alarm in case of inconsistency) and then set the relevant parameter to
download the servo parameters saved in the system to the Drive Unit.
Enter the password for system modification on the system to activate the parameter switch and
thereafter access the system servo parameter management interface to modify the relevant
parameters. Before modifying the parameters, set No.0 password privilege parameter the
corresponding value. Only in this way other parameters can be modified. The system can automatically
save the changed parameters by operating the system interface. The servo parameters will become
active in the next start.
No.0 parameter
No.1 parameter
No.98 parameter
No.99 parameter
Summary of Contents for DA98E Series