CHAPTER 8 OPERATION INTRODUCTION
58
8-7-41. RST (Reset)
To reset the value of V set and A set to 0. The values below will be reset to factory default setting when operate RST
in MENU function or command *RST:
(1) V set to 0V
(2) A set to 0A
(3) OVP is 110% of rated voltage
(4) OCP is 110% of rated current
(5) UVL is 0V
(6) Output is OFF
8-7-42. RST1 (IP address Reset)
Reset the IP address to 192.168.0.100/255.255.0.0, and clear the setting of Gateway and DNS
Note1: Some of our higher capacity models contain default ramp-up time. For faster ramp-up time,
please consult us.
Note2: The ramp-down time depends on different models. For faster ramp-down time, please consult us.