CHAPTER 8 OPERATION INTRODUCTION
43
8-6-21. RST (Reset)
To reset the value of V set and A set to 0.
The values below will be reset to factory default setting when operate RST in MENU function or command *RST:
1. V set to 0V
2. A set to 0A
3. OVP is 110% of rated voltage
4. OCP is 110% of rated current
5. UVL is 0V
6. Output is OFF
Note1: Some of our higher capacity models contain default ramp-up time. For faster ramp-up time,
please consult us.
Note2: The ramp-down time depends on different models. For faster ramp-down time, please consult us.
8-7. SETTING MENU FOR STANDARD LAN MODELS
(EQUIPPED WITH RS-485 & LAN)
(1) Press SHIFT + ENTER keys to access MENU function.
(2) Turn the Encoder to select the functions of the MENU.
(3) After entering into MENU function, press ENTER to access the selected function and setting. Press ENTER to
confirm the change. Turn the Encoder to move forward for the next function/setting. Press SHIFT + ENTER keys
to leave the mode.
(4) Please refer to
“
Table of setting MENU
” for the selections and procedures of the MENU.