11 

2.  SETTING SWITCHES: 

 

The three digits are set with the rotary switch knobs located beneath each digit.  These knobs can be 

rotated in either direction (CW or CCW), and they are "pull" removable if digit set security is desired.  

Changing one or more digits, during timing, will instantly be reflected by an equivalent change in the 

timer's display.  Setting all three digits to zero will cause instant time-out of the timer. 

 

B.   Internal Settings 

 

THE 365 DIGITAL DISPLAY TIMER MUST BE REMOVED FROM ITS HOUSING TO ALTER ANY OF 

THE FOLLOWING SETTINGS. 

 

1.  TIME RANGE: 

 

Decimal Point Location 

can be changed with the white plastic lever mounted behind the front face of 

the timer.  This lever moves into three positions.  With finger force you can change its position and at 

the  same  time  observe  the  front  of  the  timer.    NOTE  -  this  procedure  sets  the  decimal  point 

electronically as well as visually.   

 

Time Units (Sec/Min/Hr) 

are set by moving a small width metal arm in a slotted arc on the side plate 

nearest to the units (Sec/Min/Hr) window.  By depressing this arm slightly with a pencil or pen point, it 

can be moved to a new position.  The time units physically change in the timer's face and the timer is 

electronically switched to the new units as well. 

 

2.  LINE FREQUENCY: 

 

To set the proper line frequency, connect the jumper wire to either the 50 HZ or 60 HZ pin.  These 

pins are clearly marked on the side of the timer. 

 

NOTE: 

THE TIMER CHASSIS AND THE HOUSING ARE POLARIZED SO THAT THE CHASSIS CANNOT 

BE  INSERTED  INTO  ITS  HOUSING  UPSIDE-DOWN.    IF  THE  TIMER  IS  FORCED  INTO  THE  HOUSING 

UPSIDE-DOWN DAMAGE WILL RESULT.   

 

4.1.6  Main Fuse 

 

This fuse, located in a fuse block within the controller enclosure, protects the controller and sampler components 

against overloads and short circuits. 

 

For 110/120 VAC, 1PH operation use ONLY a Buss Type FNM, 4 Amp, 250 Volt Slo-Blo fuse or equal. 

For 220/240 VAC, 1PH operation use ONLY a Buss Type FNM, 2 Amp, 250 Volt Slo-Blo fuse or equal. 

 

Optional - For standard sampling systems with excess sample leg or auger. 

 

For 110/120 VAC, 1PH operation use ONLY a Buss Type FNM, 10 Amp, 250 Volt Slo-Blo fuse or equal. 

For 220/240 VAC, 1PH operation use ONLY a Buss Type FNM, 5 Amp, 250 Volt Slo-Blo fuse or equal. 

 

4.1.7  Index Relay IR-1 

 

This mechanical latching relay signals the sampler motor starter coils.  When the relay coil receives a momentary 

signal from the timer T-1 the maintained switch contacts change to the alternate position.  Upon changing position 

the opposite motor starter coil receives power, the motor starts and a sample is taken.  

 

Summary of Contents for IS TD

Page 1: ...9575 N 109 th Ave Omaha Nebraska 68142 402 330 1500 www intersystems net SAFETY INSTALLATION OPERATION MAINTENANCE M A N U A L SAMPLER Model TD No PC 522818A Revised 2006 10 26...

Page 2: ...SE RIGHT Pilot Light 10 4 1 5 Digital Display Timer T 1 Standard 10 4 1 6 Main Fuse 11 4 1 7 Index Relay IR 1 11 4 1 8 Reverse Delay Timer Relays 12 4 1 9 Terminal Strip 12 4 2 Sampler Mounted Electri...

Page 3: ...RANTY 22 List Of Illustrations Drawings FIGURE 1 1 TD SAMPLER SAFETY LABEL LOCATIONS 4 FIGURE 2 1 TYPICAL INSTALLATION MODEL TD SAMPLING SYSTEM 5 FIGURE 4 1 STANDARD NEMA 12 CONTROL PANEL DETAIL 9 FIG...

Page 4: ...r its operating environment Careless changes could result in death or serious injury to people and reduce the performance and service life of the equipment Never perform any service on this equipment...

Page 5: ...4 FIGURE 1 1 TD SAMPLER SAFETY LABEL LOCATIONS...

Page 6: ...based but which could also be volume or quantity based A sample cycle begins when an electric motor drives the slotted sample cutter through the product flow to collect a sample of the material The s...

Page 7: ...of special materials such as stainless steel or nedox coatings D Programmable Controls to sequence the sampler and the sample collection equipment E Abrasion resistant linings of urethane AR carbon s...

Page 8: ...o be sampled as in Figure 2 1 Install the sampler as it is shown and noted on the certified drawings The sampler may or may not be supplied with a partial or a whole conveyor discharge hood Provide ne...

Page 9: ...O NOT locate the controller in a hazardous area D Most applications require that the sampler be in easy view of the controller 3 7 System Wiring Refer to the certified electrical drawing s for specifi...

Page 10: ...BY COMMON SENSE CAN RESULT IN DEATH SERIOUS INJURY AND OR EQUIPMENT DAMAGE LOCKOUT POWER BEFORE PERFORMING ANY MAINTENANCE 4 1 Control Components And Their Functions FIGURE 4 1 STANDARD NEMA 12 CONTRO...

Page 11: ...ly the timer begins timing down When the illuminated display reads all zeroes 000 the timer has timed out and initiates a sampling cycle The sample pelican traverses through the product flow to collec...

Page 12: ...d the timer is electronically switched to the new units as well 2 LINE FREQUENCY To set the proper line frequency connect the jumper wire to either the 50 HZ or 60 HZ pin These pins are clearly marked...

Page 13: ...mple cutter is in a rest position Upon initiation of a sample cycle the power is routed through the normally closed contacts of the opposite limit sample to the drive motor starter The drive motor sta...

Page 14: ...ed intervals while observing all safety precautions observe the sampler as it operates Inspect for A Loose or missing hardware B Noisy motor or motor reducer bearings C Overheated motor or reducer D A...

Page 15: ...oint where the adjustment of the eye bolts will no longer permit further tightening Shorten the chain by removing a link if necessary 5 4 2 Limit Switch Adjustment Loosen and adjust the limit switch a...

Page 16: ...clutch may need adjustment if it starts to slip When following the instructions below refer to the clutch drawing page 16 A Shutoff and lockout all power electrical pneumatic and hydraulic B Shut dow...

Page 17: ...ng the new facings items 10C sprocket item 12 bushing item 11 H Turn the adjusting nut item 10D clockwise to finger tightness Tighten an additional 1 2 to 3 4 turn I Turn the adjusting nut to position...

Page 18: ...rrect Refer to certified electrical schematic Motor power off Turn on Motor starter heaters tripped Reset Motor burnt out Replace Motor thermal overload tripped Allow motor to cool reset Defective tim...

Page 19: ...lity built piece of machinery As with any machine parts do wear out and fail It is InterSystems recommendation that a small supply of spare parts be kept on hand to cover any minor breakdowns A separa...

Page 20: ...DJ LS LEVER ARM 2 18 35352 LIMIT SWITCH BRKT 2 19 35354 LIMIT SWITCH 2 20 35073 3 ID GUM RUBBER TUBE A R 21 SEE CERT DWG PELICAN DUST SEAL BRACKET 2 22 SEE CERT DWG SAMPLE PELICAN 1 23 SEE CERT DWG CU...

Page 21: ...2 522273 522274 37 1 WEDGE GUARD 522280 522281 522282 522283 522284 38 1 HORZ DRIVE GUARD 522290 522291 522292 522293 522294 ITEM NO QTY DESCRIPTION MACHINE SIZE CONVEYOR BELT WIDTH 48 54 60 66 70 29...

Page 22: ...21 FIGURE 7 1 TD SAMPLER PARTS DRAWING...

Page 23: ...r than by an Authorized Service Representative This warranty does not cover the replacement of parts inoperative because of wear occasioned by use the cost of replacing parts by a person other than an...

Reviews: