5. Troubleshooting
50
PNEG-1813
Electronic Distributor Control
Remedy:
Check wiring, wiring connections, and encoder. Repair or replace as necessary.
Message:
The VFD has faulted. Please check for proper operation of the VFD.
Reason:
This error displays when the variable frequency drive does not perform properly.
Remedy:
Repair or replace the VFD as necessary.
Message:
The bucket elevator is running. Please stop feed before moving.
Reason:
This error displays when trying to perform a move while bucket elevator is running.
Remedy:
Stop bucket elevator before performing spout move.
Message:
You cannot lockout this position because it is currently in use. Move the spout to a different
position and then lockout this position.
Reason:
This error displays when trying to lock out a spout position that is in use.
Remedy:
Move spout to a different position and then lockout this position.
Message:
You are attempting to move to the currently selected position. Please select a different position.
Reason:
This error displays when trying to move spout to current position.
Summary of Contents for PNEG-1813
Page 2: ...2 PNEG 1813 Electronic Distributor Control ...
Page 4: ...Table of Contents 4 PNEG 1813 Electronic Distributor Control ...
Page 46: ...3 Operation Procedures 46 PNEG 1813 Electronic Distributor Control NOTES ...
Page 47: ...PNEG 1813 Electronic Distributor Control 47 4 Parts Distributor Assembly ...
Page 48: ...4 Parts 48 PNEG 1813 Electronic Distributor Control NOTES ...
Page 52: ...5 Troubleshooting 52 PNEG 1813 Electronic Distributor Control NOTES ...
Page 56: ...6 Schematic and Wiring Diagrams 56 PNEG 1813 Electronic Distributor Control NOTES ...