![GSI Group PNEG-1049 Assembly And Operation Manual Download Page 27](http://html1.mh-extra.com/html/gsi-group/pneg-1049/pneg-1049_assembly-and-operation-manual_2275205027.webp)
4. Assembly
PNEG-1049
10"-12" Commercial Bin Sweep Augers
27
34. Adjust the position of the bottom motor straps to provide adequate tension on the drive belts.
The belts should allow 1/64" of deflection for every 1" of center distance between the two (2) shafts.
35. Close the front of the belt guard. Attach the front to the back with the two (2) 5/16" x 3/4" hex bolts
and nylock nuts that were previously removed.
Figure 4Y Close Belt Guard
36. Route the power cord for the motor through the electrical cord support stand top ring and the
3/4" electrical clamp. Leave a small loop of electrical cord between the clamp and the electrical
junction box on the outside of the motor. Tighten the clamp to secure the cord.