7.1.2 Assisting suction for Plus
3
system
Pumps with Plus
3
system have an assisting suction.
•
Fit the syringe and the piece of hose.
Fig. 25
Assisting suction for Plus
3
system
Sucking in dosing medium using the assisting suction for Plus
3
system
Fig. 26
Sucking in the dosing medium
1. Remove the cover from the priming chamber.
2. Push the hose as far as it will go into the valve
tube.
3. Draw up the syringe in order to create a
perceptible low pressure, and hold the syringe in
this position.
4. Dosing medium rises in the suction line, through
the valve tube to the suction hose.
5. Relieve the syringe.
6. Remove the syringe and hose and empty.
7. Close the cover.
– For HV-variant pumps, see section
7.1.3 Assisting suction for HV variant
.
– Pump without HV variant can now be started,
see section
7.1.5 Starting the pump
.