Maintenance - Customer Service Section
GENO
®
UV systems with GENO
®
-Multi BS
-CONFIDENTIAL-
Order no. 034 523 950-gb Edited by: KONS-mhug-mrie G:\BA-523950-GB_KD-H.DOC
H-6
1.3 Overview of maintenance work (every 730 days of operating duration or every 18,000
operating hours)
All service work and in addition:
Replace UV lamp with GENO
®
-UV 60 S, 120 S, 200 S.
Replace the system sensor and sensor shell (every 730 days of
operating duration or every 18,000 operating hours, at the
latest after 2 years).
Replace the flow stabilizer (every 730 days of operating
duration or every 18,000 operating hours) with operating
systems with water temperatures between 5 – 30°C.
Record all data and work performed, including repair work, in
the operation log.
Hand over the system and operation log to the operator.
If possible, if dust deposits have collected remove these from
the left housing fan carefully from inside to outside with
pressurised air.
Table H-1: Maintenance work
Type of maintenance work
What must be done
Check the UV system sensor
and calibration of the UV
system sensor Chapter H-2.
Enter the irradiance indicated in the capacity display into the
operation log. Check the operating time of the sensor.
If the operating time of the sensor is > 730 days of operating
duration or 18,000 operating hours, or the last sensor replacement
took place longer than 2 years ago, the sensor must be replaced.
Check the functioning of a
safety device that might be
installed.
If the system is switched off, the safety device must close; check
the water flow.
Check the functioning of a
temperature flushing system
that might be installed.
Dip the temperature sensor into a beaker with warm water with a
temperature > the set limit value
the valve must open.
UV 200: Check the housing
fan.
If filter elements have been added and cannot be cleaned with
pressurised air, then replace the housing fan (not the ventilator!).
Replace the UV lamp.
Replace the UV lamp after 730 days of operating duration or
18,000 operating hours (see G-1).
Check the lamp plug.
Check the lamp plug for fractures and fissures and replace if
necessary.
Rinse the UV disinfection
system.
Clean the UV system according to the operation manual of the
flushing set and check the efficiency of cleaning by removing the
protective quartz tubes and the sensor shell when the system is
empty.
Check the seals.
Check the Viton seal at the protective quartz tube and the O-ring at
the sensor shell for fractures and fissures and replace if necessary.
Check the limit value of the
irradiance.
Check the limit value of the irradiance according to table E-1 and set
it as specified in the customer service section, chapter E-6 if necessary.
Check the pre-alarm of the
irradiance.
If the limit value is o. k., slowly pull the sensor out of the sensor
shell. With 10% above the set limit value the red pre-alarm LED
must start to light up. Reset if necessary as specified in the
customer service section, chapter E-6.
Documentation.
Record all data and work performed, including repair work, in the
operation log.