GENO
®
-flushing compressor 1988 K
Order no. 015 151 963-inter Created: KONS-gmei-mrie G:\BA-151963-INTER_GENO-SPUELKOMP-1988_K.DOC
32
2.1 Integration of a flushing compressor in place of a filter with an installation length of
100 mm
Warning!
When using the filter from the connection fitting case, a new
filter cartridge must be used for each flushing operation.
For this connection type, the parts for the nominal widths ¾", 1" and
1¼" are included in the connection fitting cases ¾" - 2". In each case
the installation length is 100 mm.
Replace the on-site filter with a flushing adapter.
Fit the BOXER
®
K fine filter with double screw connection G1" on the
flushing compressor. Fit the adapter IG 1"-24 mm on the filter on the
inlet side. Then connect with the connection tubes.
Fig. D-3: Installation example of integration of a flushing compressor in place of a fine
filter