Mobile reverse osmosis system
AVRO-flex 400
Order no. 095 752 946-inter Edited by: phar-mrie G:\BA-752946-INTER_095_AVRO-FLEX_400.DOCX
40
G Troubleshooting
Even carefully designed and manufactured technical systems that are
operated properly, may experience malfunctions. Table G-1 provides
an overview of possible problems that may occur during the operation
of the systems and indicates the causes and their elimination.
The systems are equipped with an error detection and reporting sys-
tem. If an error message is displayed:
1. Press P button (= acknowledge malfunction).
2. Watch the display.
If the message reappears, compare it with table G-1.
3. If necessary, notify Grünbeck’s technical service.
Note:
The technical service definitely must be notified (refer to
gruenbeck.de) in case of malfunctions that cannot be remedied with
the information given in table G-1! When contacting the technical ser-
vice, please indicate the system designation, serial number and the
error message displayed.
Table G-1: Troubleshooting
This is what you observe This is the cause
This is what to do
Water quality deteriorated
by 50 %.
Membrane clogged.
Replace or flush the membrane
1)
.
Feed water values deteriorated. Check feed water values.
Solenoid valve does not
open
.
Coil defective or fuse F1 blown
on circuit board.
Replace coil or fuse T1A.
Solenoid valve does not
close
.
Valve contaminated.
Clean valve.
Bar appears in the dis-
play above Symbol
Close.
High-pressure pump:
Thermostat contact has re-
sponded, pump has over-
heated.
Upstream hardness monitor-
ing or water treatment locks
the system.
Wait until the pump has cooled
down again, the system will
then automatically continue to
produce.
Inspect system installed up-
stream.
Bar appears in the dis-
play above screw wrench
symbol (without further in-
dications of a malfunc-
tion).
Service interval has elapsed.
Have maintenance performed.