Mobile reverse osmosis system
AVRO-flex 400
Order no. 095 752 946-inter Edited by: phar-mrie G:\BA-752946-INTER_095_AVRO-FLEX_400.DOCX
34
3.3 Reference values / times Code 302
Display / factory
setting
Parameters
Setting
range
Comment
1. 2
Operating mode
AVRO-flex 400
Display
only
2,0000
Reference value per-
meate flow [l/h]
0 ... 9999
Note
:
The parameters 2. and 3.
must be measured and gauged
while the high-pressure pump is
running.
3,0000
Reference value con-
centrate flow [l/h]
0 ... 9999
6. 5.0
Duration of flushing
[minutes]
0 ... 99.9
Inlet (feed water) and flushing solenoid
valves.
7. 3
System run-down
time [seconds]
1 ... 99
After pressure switch for minimum pressure
responds = operational release.
9. 5
Start-up delay of
high-pressure pump
[seconds]
3 ... 99
After inlet solenoid valve opens.
A. 3
Delay time of pres-
sure switch of high-
pressure pump
[seconds]
3 ... 99
b. 000
Duration of mainte-
nance interval [days]
0 ... 365
0 = Service interval deactivated.
Acknowledgement of the maintenance
interval (bar above the "screw wrench"
symbol) by reprogramming of the
maintenance interval.
d. 40
Minimum AVRO
treatment current
[mA]
0 .... 200
Treatment current is requested at the end
of the permeate production. In case the
threshold programmed there is undershot,
Er4 is emitted.
E. 3000
AVRO maintenance
interval [h]
0.3000
Acknowledgement of the maintenance
interval by reprogramming the value.
F. 03
Delay time of PS
pump after start of
permeate production
[sec]
1 .... 99
Without function in case of AVRO-flex 300
G. 0.0
Flushing delay after
activation of pressure
switch for operational
release [minutes]
0.0 .... 99.9 Filling mode: If the pressure switch has re-
sponded uninterrupted this long, the sys-
tem flushes. If the pressure switch drops
out, the permeate production starts.