42
Changing the lubrication cycle duration t
SZ
:
As soon as the Settings menu has been selected, the active operating mode is displayed. To be
able to set the lubrication cycle duration t
SZ
, the operating mode Hour mode must be selected
with the symbol of the dial. If this is not the case, change the operating mode accordingly. An ex-
planation of how to change the operating mode can be found in Chap. 6.3.4.
After the operating mode Hour mode is displayed, the lubrication cycle duration t
SZ
and then the
number of lubrication strokes C can be set; direct access to the number of lubrication strokes C
is not possible.
In addition to the display of the active operating mode, the confirmation hook appears; the
display and the hook flash twice for visual confirmation.
In the next step, the currently set value of the lubrication cycle duration (t
SZ actual
) is shown in the
display. You now have the option of changing the value.
Changing a value of the lubrication cycle duration t
SZ
:
If you want to change the value of the lubrication cycle duration t
SZ
, move the activation and
programming key back to the action surface.
The double circle appears and the next higher (t
SZ 1
) adjustable value of the lubrication
cycle duration is shown in the display. The double circle lights up for as long as the magnet pin is
on the action surface; the other values of the lubrication cycle duration run through one after the
other (the display accelerates). However, you can also remove the activation and programming
key from the action surface and place it on the action surface again shortly afterwards in order to
reach each value individually one after the other. If the final value of the lubrication cycle duration
of t
SZ
= 240 is reached and no value was selected, the menu jumps back to t
SZ
= 01 and the run
can be started again.
When the new value you desire for the lubrication cycle duration (t
SZ new
) is shown in the display,
remove the activation and programming key from the action surface.
The confirmation hook appears; for visual confirmation, the display and the hook flash twice.
The selected new value (t
SZ new
=> t
SZ actual
) of the lubrication cycle duration has now been accepted.
The submenu now automatically continues to the values of the number of lubrication strokes.
No changing a value of the lubrication cycle duration t
SZ
:
If you do not want to change the value of the lubrication cycle duration t
SZ
, the activation and
programming key must remain away from the action area.
The confirmation hook appears; for visual confirmation, the display and the hook flash twice,
while the display shows the lubrication cycle duration t
SZ
. The submenu now automatically conti-
nues to the value of the number of lubrication strokes C.
The display first shows the currently set value for the number of lubrication strokes per pump
cycle (C
actual
). You now have the option of changing the values.
Summary of Contents for LUBRICUS LUB-V