37
6.3.4.1 Operating mode Hour mode
Term/Parameter
Shortcut
Value
Number of lubrication strokes per pump
cycle and outlet
C
adjustable, 1 ... 30
Lubrication stroke time
t
C
predefined, 7s ... 17s
Relaxation time
t
E
predefined, 2s
Pause time
t
P
calculable
Pump cycle
PZ
–
Pump cycle duration
t
PZ
calculable
Lubrication cycle
SZ
–
Lubrication cycle duration
t
SZ
adjustable, 1h ... 240h
Emptying time
EZ
–
Emptying time of a cartridge
t
EZ
calculable
The different parameters can be calculated as follows:
𝑡𝑡𝑡𝑡
𝑃𝑃𝑃𝑃𝑃𝑃𝑃𝑃
=
𝐶𝐶𝐶𝐶 ∗ 𝑡𝑡𝑡𝑡
𝐶𝐶𝐶𝐶
+ (
𝐶𝐶𝐶𝐶 −
1)
∗ 𝑡𝑡𝑡𝑡
𝐸𝐸𝐸𝐸
𝑡𝑡𝑡𝑡
𝑃𝑃𝑃𝑃
=
𝑡𝑡𝑡𝑡
𝑆𝑆𝑆𝑆𝑃𝑃𝑃𝑃
− 𝑡𝑡𝑡𝑡
𝑃𝑃𝑃𝑃𝑃𝑃𝑃𝑃
General information:
250 ml cartridge
400 ml cartridge
LUB-V with 1 outlet
=
𝑡𝑡𝑡𝑡
𝑆𝑆𝑆𝑆𝑆𝑆𝑆𝑆
∗
1687
𝐶𝐶𝐶𝐶
=
𝑡𝑡𝑡𝑡
𝑆𝑆𝑆𝑆𝑍𝑍𝑍𝑍
∗
2700
𝐶𝐶𝐶𝐶
LUB-V with 2 outlets
=
𝑡𝑡𝑡𝑡
𝑆𝑆𝑆𝑆𝑆𝑆𝑆𝑆
∗
1687
2
∗ 𝐶𝐶𝐶𝐶
=
𝑡𝑡𝑡𝑡
𝑆𝑆𝑆𝑆𝑆𝑆𝑆𝑆
∗
2700
2
∗ 𝐶𝐶𝐶𝐶
Simplified calculation of the
emptying time t
EZ
[h] depending on the selected cartridge and Lubricus
V type:
Summary of Contents for LUBRICUS LUB-V