PERFORMANCE DATA
Model
Firing Rate, BTU/hr
TDH-20, TDHC-20, TDH-24, TDHC-24
28,000
TDH-40, TDHC-40, TDH-48, TDHC-48
48,800
Injector Diameters
TDH-20
TDH-40
G20 Nat. Gas
0.94 mm
1.09 mm
No. of Orifices
8
12
G25 Nat. Gas
1.09 mm
1.19 mm
No. of Orifices
8
12
G31 Nat. Gas
0.57 mm
0.66 mm
No. of Orifices
8
12
Gas Pressure Adjustment
TDH-20
TDH-40
G20, G25
Natural Gas
mbar
8.75
8.75
in w.c.
3.5
3.5
G31
Propane
Gas
mbar
25
25
in w.c.
10
10
IMPORTANT - READ FIRST - IMPORTANT
IMPORTANT: THESE APPLIANCES MUST BE INSTALLED BY A COMPETENT PERSON IN
CONFORMITY WITH THE INSTALLATION AND SERVICING INSTRUCTIONS
AND NATIONAL REGULATIONS IN FORCE AT THE TIME. PARTICULAR
ATTENTION MUST BE PAID TO THE FOLLOWING (CE):
I. E. E. REGULATIONS FOR ELECTRICAL INSTALLATIONS
ELECTRICITY AT WORK REGULATIONS
GAS SAFETY (INSTALLATION & USE REGULATIONS
HEALTH AND SAFETY AT WORK ACT
FIRE PRECAUTIONS ACT
LOCAL AND NATIONAL BUILDING REGULATIONS
DETAILED RECOMMENDATIONS ARE CONTAINED IN INSTITUTE OF GAS
ENGINEERS PUBLISHED DOCUMENTS: IGE/UP/1, IGE/UP/2, BS6173 AND
BS5440 (CE).
THESE APPLIANCES HAVE BEEN CE-MARKED ON THE BASIS OF
COMPLIANCE WITH THE GAS APPLIANCE DIRECTIVE, EMC AND LOW
VOLTAGE DIRECTIVE FOR THE COUNTRIES, GAS TYPES AND PRESSURES
AS STATED ON THE DATA PLATE.
WARNING: FAILURE TO DISCONNECT POWER BEFORE SERVICING COULD RESULT IN
ELECTROCUTION AND DEATH.
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR
MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE
INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
WARNING: THE UNIT MUST BE INSTALLED BY PERSONNEL QUALIFIED TO WORK WITH GAS,
ELECTRICITY AND PLUMBING. UNIT MUST BE INSTALLED IN ACCORDANCE WITH
ALL APPLICABLE CODES.
WARNING: DO NOT ATTACH THE UNIT TO A TYPE “B” VENT. IT COULD CAUSE FIRE OR
PROPERTY DAMAGE.
WARNING: DO NOT CONNECT ANY PIPING TO THE PRESSURE RELIEF VALVE. IT MUST BE
FREE TO VENT STEAM AS NEEDED. TO AVOID BURNS FROM THE VENTED STEAM
THE VALVE DISCHARGE SHOULD POINT DOWNWARD.
DANGER: ELECTRICALLY GROUND THE UNIT AT THE TERMINAL PROVIDED. FAILURE TO
GROUND THE UNIT COULD RESULT IN ELECTROCUTION AND DEATH.
CAUTION: BE SURE ALL OPERATORS READ, UNDERSTAND AND FOLLOW THE OPERATING
INSTRUCTIONS, CAUTIONS AND SAFETY INSTRUCTIONS CONTAINED IN THIS
MANUAL.
CAUTION: DO NOT OVERFILL THE KETTLE WHEN COOKING, HOLDING OR CLEANING. KEEP
LIQUIDS A MINIMUM OF 2-3” (5-8 CM) BELOW THE KETTLE BODY RIM TO ALLOW
CLEARANCE FOR STIRRING, BOILING AND SAFE TRANSFER OF PRODUCT.
CAUTION: KEEP FLOORS IN FRONT OF KETTLE WORK AREA CLEAN AND DRY. IF SPILLS
OCCUR, CLEAN IMMEDIATELY TO AVOID SLIPS OR FALLS.
WARNING: KEEP WATER AND SOLUTIONS OUT OF CONTROLS AND BURNERS. NEVER USE A
HIGH PRESSURE HOSE TO CLEAN KETTLE SURFACES.
CAUTION: MOST CLEANERS ARE HARMFUL TO THE SKIN, EYES, MUCOUS MEMBRANES
AND CLOTHING. TAKE PRECAUTIONS: WEAR RUBBER GLOVES, GOGGLES OR FACE
SHIELD AND PROTECTIVE CLOTHING. CAREFULLY READ WARNINGS AND FOLLOW
DIRECTIONS ON CLEANER LABELS.
WARNING: DO NOT STAND ON OR APPLY UNNECESSARY WEIGHT OR PRESSURE ON THE KETTLE
FRONT OR POURING LIP. THIS COULD RESULT IN THE OVERLOAD AND FAILURE OF
THE TILT MECHANISM, AND POSSIBLE SERIOUS INJURY AND BURNS TO THE
OPERATOR AND OTHERS.
NOTICE: NEVER LEAVE A SANITIZER IN CONTACT WITH STAINLESS STEEL SURFACES LONGER
THAN 30 MINUTES. LONGER CONTACT CAN CAUSE CORROSION.
WARNING: FAILURE TO PERIODICALLY CHECK PRESSURE RELIEF VALVE OPERATION COULD
RESULT IN PERSONAL INJURY AND/OR DAMAGE TO EQUIPMENT.
WARNING: WHEN TESTING, AVOID EXPOSURE TO THE STEAM BLOWING OUT OF THE PRESSURE
RELIEF VALVE. DIRECT CONTACT COULD RESULT IN SEVERE BURNS.
WARNING: TO AVOID INJURY, READ AND FOLLOW ALL PRECAUTIONS STATED ON THE LABEL OF
THE WATER TREATMENT COMPOUND.
WARNING: BEFORE REPLACING ANY PARTS, DISCONNECT THE UNIT FROM THE ELECTRIC POWER
SUPPLY AND CLOSE THE MAIN GAS VALVE. ALLOW FIVE MINUTES FOR GAS TO VENT.
CAUTION: USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY THE
MANUFACTURER OR AUTHORIZED DISTRIBUTORS CAN CAUSE INJURY TO THE
OPERATOR AND DAMAGE TO THE EQUIPMENT AND WILL VOID ALL WARRANTIES.
WARNING: KEEP AREA AROUND KETTLE FREE AND CLEAR OF ALL COMBUSTIBLE MATERIALS.
FAILURE TO DO SO COULD RESULT IN FIRE OR PROPERTY DAMAGE.
CAUTION: HEATING AN EMPTY KETTLE MAY CAUSE THE RELEASE OF STEAM FROM THE
PRESSURE RELIEF VALVE.
IMPORTANT: SERVICE PERFORMED BY OTHER THAN FACTORY AUTHORIZED PERSONNEL WILL
VOID ALL WARRANTIES.
NOTICE: IT IS RECOMMENDED THAT AN INSTANT-READ THERMOMETER BE USED TO
CHECK THE INTERNAL TEMPERATURE THROUGHOUT THE COOKING PROCESS
AND AFTER THE COOKING PROCESS HAS BEEN COMPLETED TO ENSURE THE
FOOD HAS BEEN COOKED SUFFICIENTLY.
CAUTION: THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND
ABOVE AND PERSONS WITH REDUCED PHYSICAL, SENSORY OR MENTAL
CAPABILITIES OR LACK OF EXPERIENCE AND KNOWLEDGE IF THEY HAVE BEEN
GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE
IN A SAFE WAY AND UNDERSTAND THE HAZARDS INVOLVED.
CAUTION: CHILDREN SUPERVISED ARE NOT TO PLAY WITH THIS APPLIANCE.
CAUTION: CLEANING AND USER MAINTENANCE SHALL NOT BE MADE BY CHILDREN
WITHOUT SUPERVISION.
CAUTION: FOR APPLIANCES INTENDED FOR USE AT ALTITUDES EXCEEDING 2,000 M, THE
MAXIMUM ALTITUDE WILL BE STATED OR MARKED ON APPLIANCE.
Model
Firing Rate, BTU/hr
TDH-20, TDHC-20, TDH-24, TDHC-24
28,000
TDH-40, TDHC-40, TDH-48, TDHC-48
48,800
Model
Kettle
Capacity
Jacket
Capacity
Kettle
Body
Diameter
Kettle
Body
Depth
Base
Width
Base
Depth
TDH-20 (C,A)
TDHC-20 (C,A)
5 Gal.
(20 Qt.)
6 Qt
14
inches
11
inches
28
inches
24
inches
19 liter
5.7 liter
356 mm
279 mm
711 mm
610 mm
TDH-24 (C,A)
TDHC-24 (C,A)
6-Gal.
(24 Qt.)
6 Qt
14
inches
12-1/2
inches
28
inches
24
inches
23 liter
5.7 liter
356 mm
318 mm
711 mm
610 mm
TDH-40 (C,A)
TDHC-40 (C,A)
10 Gal.
(40 Qt.)
12 Qt
16-1/2
inches
14-1/2
inches
28
inches
26-3/4
inches
38 liter
11.4 liter
419 mm
368 mm
711 mm
680 mm
TDH-48 (C,A)
TDHC-48 (C,A)
12 Gal.
(48 Qt.)
12 Qt
16-1/2
inches
16
inches
28
inches
26-3/4
inches
45 liter
11.4 liter
419 mm
406 mm
711 mm
680 mm