-24-
Model G0692 (Mfg. 11/08 and Later)
blade Troubleshooting
symptom
possible Cause
Corrective action
blade teeth dull
prematurely.
1. Feed speed/pressure too low.
2. blade pitch too fine for cut.
3. impurities in workpiece.
4. blade not broken-in properly.
1. increase feed speed/pressure.
2. Check blade pitch, use a coarser-pitch blade.
3. inspect/clean/discard workpiece.
4. replace blade and follow
blade break-in on page
17.
blade teeth are broken/
missing.
1. Feed speed/pressure too high.
2. blade allowed to hop during cut.
3. blade was in contact with the
workpiece when machine was
turned
on.
4. blade tooth pitch incorrect for cut.
5. blade not broken-in correctly.
1. reduce feed pressure by relieving pressure on the
feed lever during operation.
2. allow blade to enter workpiece in a slow and controlled
manner, follow through with a smooth and even
pressure.
3. never start the blade in contact with the workpiece.
4. Check blade tooth pitch.
5. replace blade and follow
blade break-in on page
17.
Summary of Contents for G0692