background image

 

the ECU not too far. 
7.  Connect  the  unit  GRIPONE  LEONE  to  the 

main connector of plug&play loom;  
8. Reassemble the airbox and the tank; 

 
 

 

5.2

 

IMU 

placement

 

 

 

The  positioning  of  the  IMU  on  the  bike  is  very 

important. If it is not done in the correct manner, 
the control unit may not work. The IMU must be 

connected to the wiring loom where there is the 
“IM”  marker.  The  IMU  must  be  placed  in  the 

front end of the bike, far from heat and isolated 
by the vibration. Use the foam included into the 
box to isolate it. On the face of IMU you can see 

two arrows pointing to the Z axis and the Y axis. 
The Y arrow must point the front of the bike (as 

much  horizontal  as  possible).  The  Z  arrow  must 
point the ground (as much vertical as possible. 

 
 

5.3 Connecting the Remote LED  
 

GRIPONE LEONE has a remote LED that can be 
placed  near  the  dashboard  and  it  is  helpful  to 

check the funtionalities of the unit. Connect the 
remote LED to the connector with marker “RE” 

of plug&play loom. Place it where you can see it 
when  you  ride  the  bike.  By  different  typer  of 
blink,  the  remote  led  can  inform  you  about  the 

status and functions of ECU. 

lontana da essa. 
7. Collegare la centralina GRIPONE LEONE al 

connettore 

principale 

del 

cablaggio 

plug&play; 

8. Rimontare la scatola filtro, il serbatoio e la 
sella; 

 

5.2 

 

Posizionamento della 

IMU

 

 

 

 

Il  posizionamento  della  IMU  è  molto 

importante  e  se  non  fatto  correttamente,  il 

sistema  potrebbe  non  funzionare

L’IMU  va 

collegata  al  cablaggio  al  ramo  marcato  con 

“IM”.  Va  posizionata  nella  parte  anteriore 

della moto , lontana da fonti di calori dirette 

come  il  motore  e  va  isolata  dalle  vibrazioni. 

Usa  la  spugna  inclusa  nella  confezione  per 

avvolgerla e fissarla ad

 

una parte rigida della 

moto. Il posizionamento deve essere fatto in 

modo che la freccia Y punti verso il senso di 

marcia (orizzontale) e la freccia Z punti verso il 

suolo (perpendicolare). 

 

 

5.3 Collegare il Remote LED  
 

GRIPONE LEONE è dotato di un LED remoto 
che può essere posizionato sul cruscotto ed è 

utilizzato  per  verificare  le  funzionalità  della 
centralina.  Collegare  il  LED  remoto  al 

connettore del cablaggio plug&play marcato 
“RE”.  Posizionalo  in  un  punto  visibile. 
Tramite diversi tipi di lampeggi, il led remoto 

può informarti riguardo lo stato e le funzioni 
della ECU. 

 

 

 

Summary of Contents for Leone

Page 1: ...which it is installed in GRIPONE system Prima di utilizzare il sistema GRIPONE leggere attentamente tutte le pagine di questo manuale L installazione di questo dispositivo richiede attenzione Ricordati che stai installando un dispositivo su un veicolo in grado di raggiungere velocità elevate Il sistema di controllo di trazione GRIPONE è un dispositivo professionale utilizzabile nel settore agonist...

Page 2: ...is protected from excessive vibrations and surrounding elements and that it is clamped firmly When positioning the wiring make sure that the wires cannot be pinched or crushed which may cause subsequent malfunctions clamp them as necessary 2 0 Sicurezza Durante l installazione di questo prodotto si consiglia di collocare la moto in modo che non possa causare ferite o danni cadendo o spostandosi av...

Page 3: ...g the accelerating phase ATTENZIONE La centralina deve essere posizionata dove non vi sia una temperatura di esercizio superiore di 65 C e deve essere protetta da vibrazioni Localizzare una superficie adatta su cui fissare la centralina Non fissare la centralina fino a che non è terminata l installazione di tutti gli altri componenti e il cablaggio L utilizzo di un sistema di controllo trazione no...

Page 4: ... connector B of plug play harness to the factory connector of main harness previously unplugged 5 Connect the black wire of plug play loom to the negative pole of battery or to the chassis or engine 6 Lay the plug play loom by following the inside of the chassis to the point where you want to fix the GRIPONE LEONE control unit The unit can be placed under the seat or even better inside the front f...

Page 5: ...erent typer of blink the remote led can inform you about the status and functions of ECU lontana da essa 7 Collegare la centralina GRIPONE LEONE al connettore principale del cablaggio plug play 8 Rimontare la scatola filtro il serbatoio e la sella 5 2 Posizionamento della IMU Il posizionamento della IMU è molto importante e se non fatto correttamente il sistema potrebbe non funzionare L IMU va col...

Page 6: ...anti impennamento 1 lampeggio singolo Attivata il livello controllo 1 2 lampeggi singoli Attivata il livello controllo 2 3 lampeggi singoli Attivata il livello controllo 3 4 lampeggi singoli Attivata il livello controllo 4 5 lampeggi singoli Attivata il livello controllo 5 Lampeggio lungo Problema alla piattaforma inerziale Il sistema non può lavorare correttamente 6 0 Remote buttons The kit inclu...

Page 7: ...Keep pressed the red button for 4 seconds and release it For 3 seconds the ECU will cut the power on 6 1 On Off Tieni premuto il pulsante verde per 4 secondi per disattivare il sistema Con il sistema disattivato il led verde sulla centralina rimane acceso Tieni premuto il pulsante verde per 4 secondi per riattivare il sistema on mode Con il sistema attivato il led verde sulla centralina lampeggerà...

Page 8: ...U by USB cable 6 4 IMU Initialization The IMU inside the kit of GRIPONE LEONE is initialized in factory FOR THAT REASON YOU potenza cosi da far cambiare suono al motore Se risulta difficile sentire la variazione consigliamo di mantenere il regime di rotazione attorno a 5000 RPM 6 3 Livelli controllo di trazione GRIPONE LEONE è pre programmata con una mappa base che prevede un controllo di trazione...

Page 9: ...with the measurement of Z axis s offset For that reason when you start the engine can be helpfull keep the bike most straight as possible INIZIALIZZARLA Nel caso di rottura della IMU c è la possibilità di inizializzare una nuova IMU tramite i pulsanti Procedere seguendo i passi indicati Collegare la nuova IMU al cablaggio Accendere la moto Premere per 4 sec entrambi i pulsanti e rilasciarli Si acc...

Page 10: ...stema Pressione prolungata del pulsante ROSSO 3sec Attivazione controllo ECU Pressione prolungata del pulsante VERDE e ROSSO 3sec Azzeramento IMU 7 0 Program the ECU by USB cable GRIPONE LEONE is pre programmed with a base map that cover a large range of user By the buttons you can change the level of traction but you can not change the anti wheelie or the launch control If you want access to all ...

Page 11: ...meters Wait the end of procedure Disconnect the USB cable At the end of procedure the ECU is ready to be used NOTE we suggest to save the map you created so you can re load it into WINSOFT any moment you want To save the map select Save As from the menu File 7 2 Programmare la ECU Dopo l installazione di WINSOFT puoi programmare l ECU GRIPONE LEONE può essere programmata con il motore spento Colle...

Page 12: ...ne the sensitive of anti wheelie control Increase its value if you want to cut the power as soon the tire lift from the ground Reduce its value if 7 3 Parametri TRACTION CONTROL SENSITIVE stabilisce la sensibilità del controllo di trazione 20 è massimo controllo 1 è minimo controllo TRACTION CONTROL INTENSITY stabilisce la progressione del controllo di trazione Usa valori alti 12 20 se vuoi fermar...

Page 13: ...i solleva dal terreno Riduci il valore se vuoi permettere un certo impennamento prima di tagliare la potenza ANTI WHEELIE DURATION L anti impennamento taglia la potenza ogni volta che la ruota si solleva DURATION definisce la durata in centesimi di secondo della riduzione di potenza Aumenta il valore se vuoi prolungare il taglio di potenza riduci il valore se vuoi ottenere solamente un taglio brev...

Page 14: ...ruota posteriore ...

Page 15: ......

Page 16: ...designed owned and made by GUBELLINI s a s di Diego Gubellini C Via Euridia Bergianti 10 B 40059 Medicina BO Italy P IVA IT03466001207 www gripone com info gripone com ...

Reviews: