18
Only the pressure regulator and hose assembly supplied
with the grill should be used. Any replacement pressure
regulator and hose assembly must be those specified by
the grill manufacturer.
This is a liquid propane configured grill.
Do not attempt to use a natural gas supply.
Total gas consumption (per hour) of this grill with all
burners on “MAX”:
Main burner 30,000 Btu/hr.
Total
30,000 Btu/hr.
The installation of this appliance in Canada must be in
accordance with the Standard CAN/CSA-B149.2
(installation code for gas burning appliances and
equipment) and local codes.
LP GAS CYLINDER REQUIREMENTS
(20LB. CYLINDER)
A dented or rusty LP Gas Cylinder may be hazardous and
should be checked by your LP supplier. Never use a
cylinder with a damaged valve. The LP gas cylinder must
be constructed and marked in accordance with the
specifications for LP gas cylinders of the U.S. Department
of Transportation (D.O.T) or the Standard for Cylinders,
Spheres and Tubes for Transportation of Dangerous
Goods; and Commission, CAN/CSA-B339, as applicable.
The 20lb. cylinder must be provided with a shut off valve
terminating in an LP gas supply cylinder valve outlet
specified, as applicable, for connection type QCC1 is the
standard for compressed gas cylinder valve outlet and
inlet connection ANSI/CSA-V-1.
The cylinder supply system must be arranged for vapor
withdrawal. The cylinder must include a collar to protect
the cylinder valve.
Other cylinder may be acceptable for use with the
appliance provided they are compatible with the appliance
retention means.
Main Manifold operating pressure: 11” water column
(W.C.)/2.74KPA
LP Gas Cylinder must be fitted with Overfill Prevention
Device (OPD).
LP Gas Cylinder must be provided with a cylinder
connection device compatible with the connection for
outdoor cooking appliances.
LP GAS HOOK-UP
Ensure that the black plastic grommets on the LP cylinder
valve are in place and that the hose does not come into
contact with the grease tray or the grill head.
CONNECTION
Your grill is equipped with gas supply orifices for use only
with liquid propane gas. It is also equipped with a high
capacity hose/regulator assembly for connection to a
standard 20lb. LP cylinder (18-1/4” high, 12-1/4”
diameter).
TO CONNECT THE L.P. GAS SUPPLY CYLINDER
1. Make sure cylinder valve is in its full off position (turn
clockwise to stop).
2. Check cylinder valve to ensure it has proper external
male threads (type 1 connection per ANSIZ21.81).
3. Make sure all burner valves are in the off position.
4. Inspect valve connections, port and regulator
assembly. Look for any damage or debris. Remove
any debris. Inspect hose for damage. Never attempt
to use damaged or obstructed equipment. See your
local LP gas dealer for repair.
5. When connecting regulator assembly to the valve,
hand tighten the nut clockwise to a complete stop. Do
not use a wrench to tighten. Use of a wrench may
damage the quick coupling nut and result in a
hazardous condition.
GAS HOOK-UP