17
93-97 / 00220
Specifications
Display:
LCD (Liquid Crystal Display)
• 3-1/2 digits with maximum reading of 3200
• 65-segment bar graph
• icons
Accuracy:
±
(% r number of digits) at 73.4
°
F
±
9
°
F
(less than 75% relative humidity)
±
(% r number of digits) at 23.0
°
C
±
5
°
C
(less than 75% relative humidity)
Polarity Indication:
positive implied, negative indicated
Overrange Indication:
OL or -OL
Low battery indication:
-
+
Sampling:
digital: 2 times per second
analog bar graph: 12 times per second
Overload Protection:
1A/500V fast blow fuse for
µ
AmA input
10A/500V fuse for A input
Auto Power Off:
Approximately 10 minutes after last switch
or function change
Operating Temperature:
32
°
to 104
°
F (-0
°
to 40
°
C)
Storage Temperature:
-4
°
to 140
°
F (-20
°
to 60
°
C)
Temperature Coefficient: 0.083 x (specific accuracy)/
°
F, <64.4
°
F or >82.5
°
F
0.15 x (specific accuracy)/
°
C, <18
°
C or >28
°
C
Relative Humidity:
0% - 80%
Power Requirements:
two AAA-size 1.5 volt batteries
Battery Life:
1000 hours typical (with alkaline battery)
Dimensions:
3.31 x 6.89 x 1.22 in (84 x 175 x 31 mm) without
holster
3.74 x 7.56 x 1.97 in (95 x 192 x 50 mm) with holster
Replacement Parts:
Test Leads (pair) - Greenlee Part Number 500 0125.6
Protective Holster - Greenlee Part Number 500 0411.5
Fuse: 1A/500V - Greenlee Part Number 918 6844.0
Fuse: 10A/500V - Greenlee Part Number 918 6843.2