User’s Guide 
 

 

 

 

Analog Multimeter 

Model 38070 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Introduction 

Congratulations on your purchase of the Extech model 38070 Analog 
Multimeter. This device measures AC/DC Voltage, DC Current, Resistance, 
and dB, displaying measurements in analog format. Properly used, this meter 
will provide many years of reliable service. 

 
 
 
 
 
 
 
 
 
 
 
 
 

WARNING: USE EXTREME CAUTION IN THE USE OF THIS DEVICE.

 

Improper use of this device can result in injury or death. Follow all safeguards 
suggested in this manual in addition to the normal safety precautions used in 
working with electrical circuits. DO NOT service this device if you are not 
qualified to do so. 

Safety Instructions 

This meter has been designed for safe use, but must be operated with caution. 
The rules listed below must be carefully followed for safe operation. 
1. 

NEVER

 apply voltage or current to the meter that exceeds the specified 

maximum: 

Input Protection Limits 

Function Maximum 

Input 

V DC or V AC 

500V AC and DC 

mA DC 

500mA DC 

Resistance 50V 

DC/AC 

2. 

USE EXTREME CAUTION

 when working with high voltages. 

3. 

DO NOT

 measure voltage if the voltage on the "COM" input jack exceeds 

500V above earth ground. 

4. 

NEVER

 connect the meter leads across a voltage source while the 

function switch is in the current or resistance mode. Doing so can 
damage the meter. 

5. 

ALWAYS

 discharge filter capacitors in power supplies and disconnect the 

power when making resistance tests. 

6. 

ALWAYS

 turn off power and disconnect test leads before opening the 

covers to replace the fuse or battery. 

7. 

NEVER

 operate the meter unless the back cover and the battery and fuse 

covers are in place and fastened securely. 

8. 

If the equipment is used in a manner not specified by the manufacturer, 
the protection provided by the equipment may be impaired. 

 
 
 

Safety Symbols 

This symbol adjacent to another symbol, terminal or operating 

device indicates that the operator must refer to an explanation 

in the Operating Instructions to avoid personal injury or damage 

to the meter. 
This 

WARNING

 symbol indicates a potentially hazardous 

situation, which if not avoided, could result in death or serious 

injury. 
This 

CAUTION

 symbol indicates a potentially hazardous 

situation, which if not avoided, may result damage to the 

product. 
This symbol advises the user that the terminal(s) so marked 

must not be connected to a circuit point at which the voltage 

with respect to earth ground exceeds 500V. 
This symbol adjacent to one or more terminals identifies them 

as being associated with ranges that may, in normal use, be 

subjected to particularly hazardous voltages. For maximum 

safety, the meter and its test leads should not be handled when 

these terminals are energized. 
This symbol indicates that a device is protected throughout by 

double insulation or reinforced insulation. 
 
 
 
 
 

Controls and Jacks 

1. Scale 
2. Pointer 
3. Scale 

zero 

adjust 

4. 

Ohms zero adjust 

5. 

Rotary function switch 

6. 

Positive V, mA and 

 input jack 

7. 

COM input jack 

 
 
 
 

Specifications 

Function Range 

Accuracy 

500V 
250V 

50V 

DC Voltage 

10V 

± 4% of full scale 

500V 
250V 

50V 

AC Voltage 
(50/60Hz) 

10V 

± 5% of full scale 

250mA 

50Ma 

DC Current 
 

0.5mA 

± 4% of full scale 

Rx10 (10,000

Ω)

 

Resistance 

Rx1k (1,000,000

Ω)

 

± 5% of full scale 

Decibels 

-10 to +56 dB (4 ranges) 

0dB=1mW in 600

 

 
 
 
 
Max input voltage

 500V 

AC/DC 

Input Sensitivity,

 2k

Ω/

Frequency Range

 50/60Hz 

Battery

 

 

  0ne (1) 1.5V AA battery 

Fuse  

 

500mA/250 fast blow (5mmx20mm) 

Operating Temperature

 41

o

F to 104

o

F (5

o

C to 40

o

C) 

Storage Temperature

 14

o

F to 122

o

F (-10

o

C to 50

o

C) 

Operating Humidity 

Max 80% up to 87ºF (31ºC) decreasing linearly to 
50% at 104ºF (40ºC) 

Storage Humidity 

<80%  

Operating Altitude 

7000ft. (2000meters) maximum. 

Weight

  

 

  3.88oz (110g) 

Size

  

3.82x3.34x1.3” (97x65x33mm) 

Safety 

For indoor use and in accordance with the 
requirements for double insulation to IEC1010-1 
(1995): EN61010-1 (1995) Overvoltage Category II 
500V, Pollution Degree 2. UL, CE Approved 

 
 
 
 
 
 
 
 

1

2
3

4
5

6
7

WARNING

CAUTION

MAX 
500V

 

Reviews: