15
d5
Piping temp.
-30
℃~
70
℃
Real testing value
d6
Gas exhaust temperature
0
℃~
C5
℃
(125
℃
)
Real testing value
d7
Step of EEV
0
~
99
N*5
d8
Compressor running frequency
0
~
99Hz
Real testing value
d9
Compressor current
0
~
30A
Real testing value
d10
Current fan speed
0-1200
(
rpm
)
Real testing value
d11
Error code for last time
All error code
Press
first, then press
to check the “ User parameter from P0 to P7
If needed, press
second, then press
or
to adjust the current parameter.
(for example: Press
first, then press
to enter parameter P7 checking, and press
second, then
press
or
to adjust the parameter P7 Inlet water temp. Correction from -9 to 9.)
Code
Name
Scope
Default
Remark
P0
Manual defrost
0-1
0
1 Manual defrosting mode, 0 Normal mode
P1
Working mode
0-1
1
1 Heating mode
,
0 cooling mode
P2
Timer on/off
0-1
0
1 Timer on/off is under function
,
0 Timer on/off is out of
function (The setting of P4 and P5 won’t work)
P3
Water pump
0-1
0
1 Always running
,
0 Depends on the running of compressor
P4
Current time
HH:MM
00
:
00
0-23:0-59
P5
Timer on
HH:MM
00
:
00
0-23:0-59
P6
Timer off
HH:MM
00
:
00
0-23:0-59
P7
Inlet water temp.
correction
-9
~
9
0
Default setting: 0
NOTE: Under defrosting mode, P0=1.
After defrosting finished, it will be automatic enter Normal mode, P0=0.
6.2.4 System reset function
Press
and
in 10s, the system will reset and display “0000” on the controller.
6.2.5
Symbol of heating, the light will be on when it is in operation.
When defrosting, the light will flash.
6.2.6
Symbol of cooling, the light will be on when it is in operation.
Summary of Contents for Inverter Eco 10
Page 2: ......
Page 3: ...INDEX CO2 Regulation EU P1 P2 ENGLISH P3 P28 GERMAN P29 P56 ...
Page 8: ...5 2 Dimension mm Inverter Eco 7 10 Inverter Eco 12 16 ...
Page 26: ...23 ...
Page 34: ...31 2 Ausmaße Inverter Eco 7 10 Inverter Eco 12 16 ...
Page 53: ...50 8 Explosionszeichnung und Wartung 8 1 Explosionszeichnung Inverter Eco 7 10 ...
Page 54: ...51 ...
Page 60: ......
Page 61: ......
Page 62: ...A0111KDIE01 ...