14
shows the inlet water temperature and the operation mode.
Press
to stop the heat pump unit and show “OFF”
Notice : During the parameter checking and setting, press the
to quick-exit and save the current setting .
Press
again to turn on/off the machine.
6.2.2
button
Automatic mode:
Press
for 5 seconds to switch to automatic mode.(default:Smart mode)
Press
for 5 seconds again to exit automatic mode and switch to heating mode(default:Smart mode)
Note:Under Automatic mode, it is useless to set parameter P1 .
Operation logic of Auto Mode:
Set water temperature
(Tset)
Current water in
temperature
(Tset +2
℃
)
Current working
mode
After 3 minutes or
above, it will switch to
Tset (eg: 28
℃
)
Tset +2
℃
(eg:30
℃
)
Heating mode
Cooling mode
Tset (eg: 28
℃
)
Tset-2
℃
(eg: 26
℃
)
Cooling mode
Heating mode
6.2.3
and
button
Clock/unclock the display:
Hold
and
for 5 seconds to lock/Unlock the display.
Water temperature setting :
Press
or
to set the water temperature directly.
Parameter checking :
Press
first, then press
to check the “ User parameter from d0 to d11
Code
Condition
Scope
Remark
d0
IPM mould temperature
0-120
℃
Real testing value
d1
Inlet water temp.
-9
℃~
99
℃
Real testing value
d2
Outlet water temp.
-9
℃~
99
℃
Real testing value
d3
Ambient temp.
-30
℃~
70
℃
Real testing value
d4
Frequency limitation code
0,1,2,4,8,16
Real testing value
Summary of Contents for Inverter Eco 10
Page 2: ......
Page 3: ...INDEX CO2 Regulation EU P1 P2 ENGLISH P3 P28 GERMAN P29 P56 ...
Page 8: ...5 2 Dimension mm Inverter Eco 7 10 Inverter Eco 12 16 ...
Page 26: ...23 ...
Page 34: ...31 2 Ausmaße Inverter Eco 7 10 Inverter Eco 12 16 ...
Page 53: ...50 8 Explosionszeichnung und Wartung 8 1 Explosionszeichnung Inverter Eco 7 10 ...
Page 54: ...51 ...
Page 60: ......
Page 61: ......
Page 62: ...A0111KDIE01 ...