11
Water Inlet & outlet junction
1. Use the pipe tape to connect the water
Inlet & outlet junction onto the heat
pump
2. Install the two joints like the picture
shows
3. Screw them onto the water Inlet &
outlet junction
Cable wiring
1. Connect the power supply wire
through the white hole like the picture
shows.
2. Fix the other side on joints inside the
electric box.
Water pump wiring
1. Connect the water pump wire through
the white hole marked
2. Fix the other side on joints inside the
electric box.