60
Air to Water Heat Pump
Service Manual- Versati Series
DPOUSPM
3.2.3.15 Test Mode
The test mode setting is as follow:
(1). Operate the wired controller to let the heating/cooling operation OFF and water heating OFF and then
hold down ESC and Return buttons at the same time for 10 seconds into test mode.
,QWHVWPRGHH[FHSWŸź6HW(VFDQG5HWXUQEXWWRQVDOOEXWWRQVDUHVKLHOGHG
(3). In test mode
3UHVVŸRUźEXWWRQWRVHOHFWWKHW\SHRIWHVWPRGH7KHUHDUHW\SHVLQWRWDOIRUVHOHFWLRQ
1
If the minute display area of CLOCK is 01, it means test mode 1---cooling operation.
2
If the minute display area of CLOCK is 02, it means test mode 2---heating operation.
7KHFRPSUHVVRUƍVIUHTXHQF\GXULQJWKHRSHUDWLRQZLOOEHDGMXVWHGDFFRUGLQJWRWKHGLIIHUHQFHEHWZHHQWKH
actual leaving water temperature and target set temperature, so test mode is mainly for nominal performance
testing.
3.3 Installation
(1) Open front panel of indoor unit and release the clasp of wired controller as shown in Fig 1.
(2) Manually remove the LCD of wired controller with caution.
Summary of Contents for VERSATI SERIES
Page 1: ...AIR TO WATER HEAT PUMP SERVICE MANUAL VERSATI SERIES T1 R410A 50Hz 60Hz GC201202 ...
Page 4: ...1 Air to Water Heat Pump Service Manual Versati Series PRODUCT QSPEVDU ...
Page 15: ...12 Air to Water Heat Pump Service Manual Versati Series CONTROL DPOUSPM ...
Page 66: ...63 Air to Water Heat Pump Service Manual Versati Series INSTALLATION JOTUBMMBUJPO ...
Page 92: ...89 Air to Water Heat Pump Service Manual Versati Series JOTUBMMBUJPO GRS CQ16Pd Na H ...
Page 102: ...99 Air to Water Heat Pump Service Manual Versati Series MAINTENANCE NBJOUFOBODF ...
Page 128: ...125 Air to Water Heat Pump Service Manual Versati Series NBJOUFOBODF Fig 14 ...
Page 158: ...JF00300495 ...