105
Air to Water Heat Pump
Service Manual- Versati Series
NBJOUFOBODF
(2) Comp Low- pressure Protection E3
Comp Low-pressure Protection E3
Check if comp low-pressure switch
is broken or the wiring is loose.
Check the fans
Replace comp
low- pressure or rewire
yes
no
Check if the fans stop running or reverse
yes
no
Check if the system has leaked
Repair the leakage of system
pipe and add refrigerant
according to the required volume
yes
(3) Comp Discharge Temp Protection E4
Comp Discharge Temp Protection E4
Measure if the exhaust
temperature of compressor
reaches120
ć
Replace the
electric
expansion valve
no
yes
yes
no
The refrigerant of the system is
not enough and add refrigerant
according to the required volume
yes
Replace the corresponding
exhaust temperature sensor
Measure if the
resistance of temperature
sensor is correct
yes
Replace the mainboard
of outdoor unit
no
Check if the the electric
expansion valve is blocked
Check if the system has leaked
Repair the leakage of system
pipe and add refrigerant
according to the required volume
no
Summary of Contents for VERSATI SERIES
Page 1: ...AIR TO WATER HEAT PUMP SERVICE MANUAL VERSATI SERIES T1 R410A 50Hz 60Hz GC201202 ...
Page 4: ...1 Air to Water Heat Pump Service Manual Versati Series PRODUCT QSPEVDU ...
Page 15: ...12 Air to Water Heat Pump Service Manual Versati Series CONTROL DPOUSPM ...
Page 66: ...63 Air to Water Heat Pump Service Manual Versati Series INSTALLATION JOTUBMMBUJPO ...
Page 92: ...89 Air to Water Heat Pump Service Manual Versati Series JOTUBMMBUJPO GRS CQ16Pd Na H ...
Page 102: ...99 Air to Water Heat Pump Service Manual Versati Series MAINTENANCE NBJOUFOBODF ...
Page 128: ...125 Air to Water Heat Pump Service Manual Versati Series NBJOUFOBODF Fig 14 ...
Page 158: ...JF00300495 ...