72
U-MATCH Air
Conditioners
Service Manual
)RUPWKHWLJKWHQLQJWRUTXHQHHGHGIRUWLJKWHQLQJQXW
Pipe diameter
7LJKWHQLQJWRUTXH
1/4"
1ÂP
3/8"
1ÂP
5/8"
1ÂP
1/2"
1ÂP
3/4"
1-75
1ÂP
Curvature of piping shall not be too small, or otherwise piping may be broken. So installation personnel
should use a pipe bender to bend pipes.
Upward or longitudinal welding joint method is usually applied to the welding of pipelines. The welding
method that mouth of pipe is downward (face-down welding) should be avoided as far as possible,
because such method is prone to welding defects and even would cause leakage, as shown in Figure 3-1-
3.
Bumer
Solder
Downward facing
Side facing
Recommended methed
Upward facing
Figure 3-1-3
Uninsulated connecting pipes and connectors should be packed with sponge and tied with plastic adhesive
tapes.
2. Vacuum-pumping and leak detection
Dismantle the bonnet of refrigerant valve and air valve.
$OLJQZLWKWKHFHQWHURISLSLQJDQGDGHTXDWHO\WLJKWHQQXWVRIFRQQHFWLQJSLSHVE\KDQG
Tighten the nuts with a spanner.
Remove the one way valve cap of air valve.
Unscrew the spool of refrigerant valve for 1/4 turn with a socket head wrench, and at the same time push
up the spool of air valve with a screwdriver to let air give off.
Air exhaust continues for 15 seconds until coolant gas appears, immediately shut off one way valve and
tighten the valve cap.
Totally open the spool of refrigerant valve and air value (as shown in Figure 3-1-4)
One-Way Valve
Gas Valve
/LTXLG9
alve
Valve Cap
Inner Hexagon
Spanner
Screwdriver
Valve Stem
Figure 3-1-4
Summary of Contents for GKH12K3BI
Page 1: ...U MATCH AIR CONDITIONERS SERVICE MANUAL T1 R410A 50Hz...
Page 4: ...1 U MATCH Air Conditioners Service Manual PRODUCT QSPEVDU...
Page 31: ...28 U MATCH Air Conditioners Service Manual CONTROL DPOUSPM...
Page 33: ...30 U MATCH Air Conditioners Service Manual DPOUSPM 1 2 Heating Operation...
Page 50: ...47 U MATCH Air Conditioners Service Manual INSTALLATION...
Page 86: ...83 U MATCH Air Conditioners Service Manual MAINTENANCE...
Page 93: ...90 U MATCH Air Conditioners Service Manual Malfunction display E6 Communications Failure...
Page 111: ...108 U MATCH Air Conditioners Service Manual Model GTH30K3B1I Model GTH60K3B2I...
Page 151: ...148 U MATCH Air Conditioners Service Manual 2 Model GUHN24NK3AO Exploded Views...
Page 156: ...153 U MATCH Air Conditioners Service Manual 5 Model GUHN42NM3AO GUHN48NM3A1O Exploded Views...
Page 158: ...155 U MATCH Air Conditioners Service Manual 6 Model GUHN60NM3AO Exploded Views...
Page 160: ...157 U MATCH Air Conditioners Service Manual 7 Model GUHN60NM3A2O Exploded Views...
Page 165: ...162 U MATCH Air Conditioners Service Manual 2 Model GUHN24NK3AO Exploded Views...
Page 168: ...165 U MATCH Air Conditioners Service Manual 4 Model GUHN36NK3AO GUHN36NM3AO Exploded Views...
Page 173: ...170 U MATCH Air Conditioners Service Manual 6 Model GUHN60NM3A2O Exploded Views...
Page 175: ...172 U MATCH Air Conditioners Service Manual 7 Model GUCN42NM3AO Exploded Views...
Page 177: ...174 U MATCH Air Conditioners Service Manual 8 Model GUCN48NM3AO Exploded Views...
Page 189: ...186 U MATCH Air Conditioners Service Manual 3 Model GKH30K3B1I Exploded Views...
Page 191: ...188 U MATCH Air Conditioners Service Manual 4 Model GKH42K3B1I GKH48K3B3I Exploded Views...
Page 193: ...190 U MATCH Air Conditioners Service Manual 5 Model GKH60K3B2I Exploded Views...
Page 209: ...JF00300193...