75
U-MATCH Air
Conditioners
Service Manual
6SHFL¿FDWLRQRI&RQQHFWLRQ3LSH
Model
External Diameter
Maximum Length
of Connection
Pipe
Maximum Difference
in Height between
Outdoor and Indoor
Unit
Additional Charge
of Refrigerant
Gas Pipe
/LTXLG3LSH
(m)
(m)
(g/m)
*8+11.$2
ĭ
3/8"
ĭ
1/4"
15
15
*8+11.$2
ĭ
1/2"
ĭ
1/4"
15
15
*8+11.$2
*8+11.$2
ĭ
5/8"
ĭ
3/8"
15
*8+11.$2
*8+11.$2
ĭ
3/4"
ĭ
1/2"
GUHN36NM3AO
GUHN42NM3AO
GUHN48NM3A1O
*8+110$2
*8+110$2
GUCN42NM3AO
ĭ
3/4"
ĭ
ij
25
GUCN48NM3AO
(/(&75,&:,5,1*:25.
4.1 Wiring Principle
4.1.1 General
Perform wiring of the power supply in conformance with the regulations of the local electric company.
For the control wires connecting indoor units, and between indoor and outdoor units, use of double-core
shield wires is recommended to prevent noise trouble.
Be sure to set the earth leakage breaker and the switches to the power supply section of the indoor unit.
Supply power to each outdoor unit and provide an earth leakage breaker or hand switch for each outdoor
unit.
Store wiring system for control and refrigerant piping system in the same line.
Arrange the cables so that the electric wires do not come to contact with high-temperature part of the
refrigerant pipe; otherwise coating melts and an accident may be caused.
'RQRWWXUQRQSRZHURIWKHLQGRRUXQLWXQWLOYDFXXPLQJRIWKHUHIULJHUDQWSLSHZLOO¿QLVK
Installation should be conducted by National Wiring Regulation.
The rated voltage and exclusive power supply must be adopted for the air conditioners.
7KHSRZHUFDEOHVKRXOGEHUHOLDEOHDQG¿[HGLQRUGHUWRDYRLGWKHZLULQJWHUPLQDOEHVXIIHUHGIURPIRUFH
And do not drag the power cable forcibly.
The wire diameter of power cable should be large enough, if power cable and connection wire be
damaged, it should be replaced by the exclusive cable.
All electric installation must be done by professional personnel according to local law, regulation and this
manual.
It should be reliably earthed, and it should be connected to the special earth device, the installation work
should be operated by the professional.
The creepage protect switch and air switch must be installed.
Air switch should have the thermal dropout and magnetic dropout function, in order to avoid the short
circuit and overload.
The on spot connection should refer to the circuit diagram, which is stuck on the unit body.
7KHXQLWVKRXOGEHUHOLDEO\HDUWKLILWLVLPSURSHUO\HDUWKHGWKDWPD\FDXVHHOHFWULFVKRFNRU¿UH
Air conditioner is the “I” class electric appliance, thus please do conduct reliable grounding measure.
The yellow-green two-color wiring of air conditioner is grounding wire and cannot be used for other
SXUSRVHV,WFDQQRWEHFXWRIIDQGEH¿[HGE\VFUHZRWKHUZLVHLWZRXOGFDXVHHOHFWULFVKRFN
The user must offer the reliable grounding terminal. Please don’t connect the grounding wire to the
following places:
a. Water pipe;
Summary of Contents for GKH12K3BI
Page 1: ...U MATCH AIR CONDITIONERS SERVICE MANUAL T1 R410A 50Hz...
Page 4: ...1 U MATCH Air Conditioners Service Manual PRODUCT QSPEVDU...
Page 31: ...28 U MATCH Air Conditioners Service Manual CONTROL DPOUSPM...
Page 33: ...30 U MATCH Air Conditioners Service Manual DPOUSPM 1 2 Heating Operation...
Page 50: ...47 U MATCH Air Conditioners Service Manual INSTALLATION...
Page 86: ...83 U MATCH Air Conditioners Service Manual MAINTENANCE...
Page 93: ...90 U MATCH Air Conditioners Service Manual Malfunction display E6 Communications Failure...
Page 111: ...108 U MATCH Air Conditioners Service Manual Model GTH30K3B1I Model GTH60K3B2I...
Page 151: ...148 U MATCH Air Conditioners Service Manual 2 Model GUHN24NK3AO Exploded Views...
Page 156: ...153 U MATCH Air Conditioners Service Manual 5 Model GUHN42NM3AO GUHN48NM3A1O Exploded Views...
Page 158: ...155 U MATCH Air Conditioners Service Manual 6 Model GUHN60NM3AO Exploded Views...
Page 160: ...157 U MATCH Air Conditioners Service Manual 7 Model GUHN60NM3A2O Exploded Views...
Page 165: ...162 U MATCH Air Conditioners Service Manual 2 Model GUHN24NK3AO Exploded Views...
Page 168: ...165 U MATCH Air Conditioners Service Manual 4 Model GUHN36NK3AO GUHN36NM3AO Exploded Views...
Page 173: ...170 U MATCH Air Conditioners Service Manual 6 Model GUHN60NM3A2O Exploded Views...
Page 175: ...172 U MATCH Air Conditioners Service Manual 7 Model GUCN42NM3AO Exploded Views...
Page 177: ...174 U MATCH Air Conditioners Service Manual 8 Model GUCN48NM3AO Exploded Views...
Page 189: ...186 U MATCH Air Conditioners Service Manual 3 Model GKH30K3B1I Exploded Views...
Page 191: ...188 U MATCH Air Conditioners Service Manual 4 Model GKH42K3B1I GKH48K3B3I Exploded Views...
Page 193: ...190 U MATCH Air Conditioners Service Manual 5 Model GKH60K3B2I Exploded Views...
Page 209: ...JF00300193...