32
U-MATCH Air
Conditioners
Service Manual
DPOUSPM
2.3 Heating Mode
1S 20S
10S
15S
45S
60S
Compressor
Outdoor fan
Indoor fan
4-way valve
Starting up
Manual shutdown
Time
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
Heating Mode
Operation at
a set speed
Operation in blowing
after heat state
Operation under
normal conditions
Cold blast
prevention
Auxiliary heating
When T
amb.
7
preset
-1
o
C, the unit begins heating operation and the compressor and the outdoor fan are
running; and the indoor fan is running at a set speed according to cold fan prevention conditions.
When T
amb.
7
preset
+1
o
C, the compressor and the outdoor fan stop running and the four-way valve keeps
energized; and the indoor fan is running according to afterheat blowing conditions.
When T
Set
-1
o
C< T
amb.
< T
preset
+1
o
C, the unit keeps in the previous operation state.
2.4 Defrosting
1S
10S
10S
Defrosting
Time
Cold blast
prevention
Compressor
Outdoor fan
Indoor fan
4-way valve
Auxiliary heating
ON
ON
OFF
ON
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
Enter the
defrosting mode
Withdraw the
defrosting mode
Operation at
a set speed
Operation under
normal conditions
Defrosting start conditions: after the heating operation runs for an accumulated period of 44 minutes and
the compressor continues to operate for 4 hours and 50 seconds, and a one-minute duration of T
cond.
o
Cis
GHWHFWHGWKHXQLWEHJLQVGHIURVWLQJ,IDQDX[LOLDU\KHDWHULVDYDLODEOHLWPXVWEHVWRSSHG¿UVWO\DQGDIWHU
seconds, the four-way valve, the indoor fan, the outdoor fan and the compressor will run compulsively.
Defrosting completion conditions: when defrosting runs 10 minutes or T
cond.
o
C, defrosting will be
completed. In such case, the four-way valve is running, the outdoor fan is running, the compressor is running
compulsively, and the indoor fan operates according to cooling fan proof conditions.
Summary of Contents for GKH12K3BI
Page 1: ...U MATCH AIR CONDITIONERS SERVICE MANUAL T1 R410A 50Hz...
Page 4: ...1 U MATCH Air Conditioners Service Manual PRODUCT QSPEVDU...
Page 31: ...28 U MATCH Air Conditioners Service Manual CONTROL DPOUSPM...
Page 33: ...30 U MATCH Air Conditioners Service Manual DPOUSPM 1 2 Heating Operation...
Page 50: ...47 U MATCH Air Conditioners Service Manual INSTALLATION...
Page 86: ...83 U MATCH Air Conditioners Service Manual MAINTENANCE...
Page 93: ...90 U MATCH Air Conditioners Service Manual Malfunction display E6 Communications Failure...
Page 111: ...108 U MATCH Air Conditioners Service Manual Model GTH30K3B1I Model GTH60K3B2I...
Page 151: ...148 U MATCH Air Conditioners Service Manual 2 Model GUHN24NK3AO Exploded Views...
Page 156: ...153 U MATCH Air Conditioners Service Manual 5 Model GUHN42NM3AO GUHN48NM3A1O Exploded Views...
Page 158: ...155 U MATCH Air Conditioners Service Manual 6 Model GUHN60NM3AO Exploded Views...
Page 160: ...157 U MATCH Air Conditioners Service Manual 7 Model GUHN60NM3A2O Exploded Views...
Page 165: ...162 U MATCH Air Conditioners Service Manual 2 Model GUHN24NK3AO Exploded Views...
Page 168: ...165 U MATCH Air Conditioners Service Manual 4 Model GUHN36NK3AO GUHN36NM3AO Exploded Views...
Page 173: ...170 U MATCH Air Conditioners Service Manual 6 Model GUHN60NM3A2O Exploded Views...
Page 175: ...172 U MATCH Air Conditioners Service Manual 7 Model GUCN42NM3AO Exploded Views...
Page 177: ...174 U MATCH Air Conditioners Service Manual 8 Model GUCN48NM3AO Exploded Views...
Page 189: ...186 U MATCH Air Conditioners Service Manual 3 Model GKH30K3B1I Exploded Views...
Page 191: ...188 U MATCH Air Conditioners Service Manual 4 Model GKH42K3B1I GKH48K3B3I Exploded Views...
Page 193: ...190 U MATCH Air Conditioners Service Manual 5 Model GKH60K3B2I Exploded Views...
Page 209: ...JF00300193...