Chapter III Malfunction Diagnosis and Troubleshooting
Great Wall Baoding Internal Combustion Engine
Manufacturing Company Limited
111
Engagement malfunction between
the pinion and the gear ring
Turn the start switch to the
―ST‖ Position and check
whether there is a voltage on the terminal
―S‖ of
solenoid switch
In this case, check whether the voltage for the
electromagnetic switch connector 3BW of
restarting relay is normal
Yes
No
Or
Serious wear
between the pinion
and the gear ring
High slipping
resistance for starter
Repair or replace the
starter and replace
the gear ring
Repair or replace the
starter.
Normal
Abnormal
Open circuit or connection
malfunction
between
the
starting
switch
and
the
electromagnetic switch
Check whether there is
a voltage at the starting
switch
connector
of
restarting relay.
Repair it
Connection malfunction
of the starting switch
Open circuit or connection
malfunction between the
starting switch and the
storage battery
Yes
No
Replace the
starting switch
Repair it